HIGH RANGE OUTPUT (14)
Provides a post-crossover high range signal. Signals which appear at this jack may be processed by the chorus
circuit.
NOTE:
Signal level of high and low range crossover outputs is controlled by the master volume control.
CHORUS IN/OUT SWITCH (15)
Used to activate/defeat the chorus circuit. To activate the circuit, depress the switch to its "in" position.
NOTE:
Chorus footswitch "overrides" push switch.
RATE CONTROL (16)
Controls the sweep rate (frequency) of the chorus effect.
DEPTH CONTROL (17)
Controls the depth (intensity) of the chorus effect.
PREAMP OUT/POWER AMP IN (18)
These jacks are provided for in-line patching of effects devices. To patch an effects unit, connect the Preamp
Output to the Input of the device. Next, connect the output of the device to the Power Amp Input (high-quality
shielded cables must be used for these connections). The Preamp Output can also be used to route the amplified
signal to a mixing console, tape recorder, etc. Connect the Preamp Output, using a shielded cable, to an input of
the tape recorder, mixer, etc. This patch does not affect the operation of the amplifier.
NOTE:
The preamp output level is approximately 1 volt RMS and is of relatively low impedance (600 ohms).
Any effects device used in this effects loop must be capable of receiving 1 volt input and providing 1 volt output
in order to properly drive the power amp. The Power Amp Input has an internal switch which disconnects the
internal preamp.
POWER LED (19)
Illuminates when AC power is being supplied to the amp.
POWER SWITCH (20)
Depress the switch to the "On" position. The red pilot light (LED) will illuminate indicating power is being
supplied to the unit.
TNT
MADE IN U.S.A.
120 VAC
1 WISimMXiC IV <wQc if
tOUPWt"T
A PRODUCT OF PEAVEY ELECTRONICS COAP.
MERIDIAN, MS
BUiLT U*OCR U.S. PATENT NO- OW.053
LINE (MAINS) CORD RETAINERS (21)
Allow storage of mains cable for travel.
LINE CORD (120 V PRODUCTS ONLY) (22)
For your safety, we have incorporated a three-wire line (mains) cable with proper grounding facilities. It is not
advisable to remove the ground pin under any circumstances. If it is necessary to use the equipment without
proper grounding facilities, suitable grounding adaptors should be used. Less noise and greatly reduced shock
hazard exists when the unit is operated with the proper grounded receptacles.