9
TO ADJUST THREAD TAKE-UP SPRING
The take-up spring S2, Fig. 23 should usually
have just enough movement so that it will be through
acting and will rest against upper end of spring reg¬
ulator
R2 when
needle
is
1/16 inch above material
on its downward stroke.
The spring should act a slight
amount as the thread passes around the bottom of the
hook
and
also
as the thread
is
cast off the hook.
To
set take-up
spring,
loosen
set screw
and, by means of stud U2, position spring regulator
required.
Then tighten screw T2.
T2
as
TO ADJUST THE BOBBIN CASE OPENER
Remove
slide
plate
and
loosen
hook post
screws N2,
Fig. 22.
Set bobbin case opener P2 so
that it touches the bobbin case Q2 as lightly as pos¬
sible, yet turns the bobbin case enough to make a suf¬
ficient opening for free thread passage between throat
plate and bobbin case.
Then tighten screws N2 and
replace slide plate.
Fig. 22
Fig. 23
To regulate
tension
on take-up spring, first
be sure screw T2 is tight.
Then turn stud U2 over to
the left to increase tension or over to therightto de¬
crease' tension.
The take-up spring may require different ten¬
sion
settings
for
different
sizes
of
thread;
heavy
thread requires more tension than light thread.
The above instructions apply to average sew¬
ing.
Adjustments
in both
stroke and
tension
may
have to be made to suit special conditions.

Advertisement