IMPORTANT: Only fully qualified personnel should attempt hydraulic maintenance or repair.
5.9.
To check the oil level, fully lower the jack. Remove the two bolts that hold the black cover in place and prise out the cover from between
the side walls of the jack. Remove oil filler plug (fig.2). The correct level is just below the bottom of the plug. If oil level is low, fill as
required. Replace cover. NOTE: Use a good quality jack oil, such as SEALEY HYDRAULIC JACK OIL.
WARNING! DO NOT use brake fluid, or any fluid other than hydraulic jack oil as this may cause serious damage to the jack and will
invalidate the warranty.
5.10.
When draining the oil make sure that no dirt is allowed to enter the hydraulic system.
IMPORTANT: NO RESPONSIBILITY IS ACCEPTED FOR INCORRECT USE OF THIS PRODUCT.
Hydraulic products are only repaired by local service agents. We have service/repair agents in all parts of the UK.
DO NOT return jacks to us. Please telephone us on 01284 757500 to obtain the address and 'phone number of your local agent.
If jack is under guarantee contact your local Sealey stockist.
De-commissioning the Jack. Should the jack become completely unserviceable and require disposal, draw off the oil into an approved
container and dispose of the jack and the oil according to local regulations.
6.
TROUBLE SHOOTING
6.1.
IF JACK WILL NOT LIFT LOAD
6.1.1. Oil level may be low. Check oil level as described in section 5.6. and top up if necessary.
6.1.2. To ensure complete distribution of the oil go through the following procedure:
Close the release valve and manually pull the lifting arm up to its full height.
Open the release valve and, by stepping on the saddle, force the arm to lower as rapidly as possible. Repeat this operation three or
four times.
This procedure also thoroughly flushes the valves and in most cases will restore the jack to full working order. The jack may have air
trapped in the system. To eliminate trapped air open the release valve and pump the handle through its full stroke six times. Close
release valve.
6.1.3. After several months of service the pump 'O' ring seal may become worn. If this is suspected take the jack to an approved agent for
servicing.
6.1.4. The release valve may be held open by dirt on the valve seat. Flush by pulling the lifting arm up and down several times manually while
the release valve is open.
6.1.5.
The load is heavier than 2 tonnes and the overload valve has operated. Remove load obtain higher capacity jack. The overload valve is factory
set and should not be altered.
6.2.
IF JACK WILL NOT HOLD THE LOAD
6.2.1. The discharge valve may be held open by dirt on the seat. Perform the procedure described in section 6.1.2. If this does not solve the
problem take the jack to an approved agent for servicing.
6.2.2. Where a jack has received heavy service the ram cup seal may become worn. If this is suspected take the jack to an approved agent
for servicing.
6.2.3. Release valve partially open. Fully close release valve.
6.3.
IF JACK WILL NOT LOWER COMPLETELY
6.3.1. The lifting arm return spring may be broken or unhooked. Replace return spring.
6.3.2. Jack requires lubrication. Clean and oil all moving parts in the lifting arm mechanism.
6.3.3. Hydraulic unit is overfilled with oil. Drain off excess oil.
6.4.
JACK WILL NOT LIFT FULL 2 TONNE LOAD
6.4.1. Piston 'O' ring seal may have become worn. If this is suspected take the jack to an approved agent for servicing.
6.4.2. The jack may have air trapped in the system. See section 6.1.2.
6.4.3. Jack frame/link system distorted due to overloading or poor positioning. Return to an approved service agent for replacement of
damaged parts.
ENVIRONMENT PROTECTION
Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted,
taken to a recycling centre and disposed of in a manner which is compatible with the environment. When the product
becomes completely unserviceable and requires disposal, drain any fluids (if applicable) into approved containers and
dispose of the product and fluids according to local regulations.
Note: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior
notice. Please note that other versions of this product are available. If you require documentation for alternative versions, please email or call
our technical team on technical@sealey.co.uk or 01284 757505.
Important: No Liability is accepted for incorrect use of this product.
Warranty: Guarantee is 12 months from purchase date, proof of which is required for any claim.
Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR
01284 757500
Original Language Version
© Jack Sealey Limited
sales@sealey.co.uk
REGISTER YOUR
PURCHASE HERE
www.sealey.co.uk
1020LE.V4 SERIES Issue 5 26/02/24

Advertisement

loading

This manual is also suitable for:

1020le series