Download Print this page
Abtus AVS-SSR8/2 Installation Manual

Abtus AVS-SSR8/2 Installation Manual

Universal projector and motorized screen controller

Advertisement

Quick Links

RS-232 PROGRAMMING
4. Reading and confirming the programmed projector
control code and Projector communication parameter
Header code (4 byte) + Data code length (1 byte) + Command ID (3 byte) +
Data code (2 byte).
Header code : 53H 45H 54H 52H
Data code length : 02H
Command ID : 53H 54H 53H
Data code : XXH YYH
XXH YYH => the respective code that has been programmed as followed:
(1). 50H 4EH : Projector “Power ON” RS232 Control code.
(2). 50H 46H : Projector “Power OFF” RS232 Control code.
(3). 56H 31H : Projector “Input Source-1” RS232 Control code.
(4). 50H 31H : Projector “Input source-2” RS232 Control code.
(5). 42H 55H : Projector “Communication Parameter” set code.
Example:
Eg1 : To retrieved POWER ON RS232 Control code.
Transmitted code : 53 45 54 52 02 53 54 53 50 4E
Return Code for
POWER ON
02 00 00 00 00 02
Eg 2 : To retrieved the projector Communication Parameter
Transmitted code : 53 45 54 52 02 53 54 53 42 55
Return Code for
Baud rate : 9600bps.
Data length : 8bits.
Parity : No Parity.
03 00
www.abtussingapore.com
Installation Guide
AVS-SSR8/2 (Universal Projector and Motorized Screen Controller)
AVS-SSR8/1 is a Universal Motorized Screen and Projector Controller with IR learning. It can
be easily be integrated into a Home Theater, a Media Class Room, a Meeting Room and any
other applications. It is also able to integrate with any third party central control system with
simple integration with direct power control of 120V 50/60Hz.
Integrated with IR/RS-232 projector control capability in one single controller. With the
programming software, projector control can be set easily. It is also integrated with a self-
contain universal IR learning function which enables the switcher to be program to control
any brand or model of projector that are out in the market.
Technical Specifications
CONTROL:
Hard button, IR Remote or Dry Contact Closure (Voltage Free)
I/O PORT:
5 X 5.0mm Screw Type Connector
(AC-N, AC-L, Common, Screen Up and Screen Down)
1x4 port 3.8mm screw type terminal block (Dry contact control)
1x3 port 3.8mm screw type terminal block (RS-232)
1x2 port 3.8mm screw type terminal block (IR)
CURRENT RATING:
MAX. Load 1.8A
HOUSING:
ABS
DIMENSION / WEIGHT:
70mm X 120mm X 40mm / 130g
POWER SOURCE:
120V 50/60Hz
ACCESSORIES:
1 x IR Remote Controller and 1x IR probe
* Specifications are subject to changes without noticfication
ABtUS AVS-SSR8/2
AVS-SSR8/2

Advertisement

loading

Summary of Contents for Abtus AVS-SSR8/2

  • Page 1 Example: Eg1 : To retrieved POWER ON RS232 Control code. AVS-SSR8/2 (Universal Projector and Motorized Screen Controller) Transmitted code : 53 45 54 52 02 53 54 53 50 4E AVS-SSR8/1 is a Universal Motorized Screen and Projector Controller with IR learning. It can...
  • Page 2 Contact closure must set close for 1.5 seconds. Transmitted Code 53 45 54 520253 50 4602 00 (Warranty void if damaged is caused by inappropriate use.) Returned Code 52 54 55 4E0253 50 460200 to be continued.. ABtUS AVS-SSR8/2 ABtUS AVS-SSR8/2...
  • Page 3 The data sent from the computer to the controller is transmitted in the Hex format shown below: Header code (4 byte) + Data code length (1 byte) + Command ID (3 byte) + Data code (maxium : 20 byte). to be continued.. ABtUS AVS-SSR8/2 ABtUS AVS-SSR8/2...
  • Page 4 (2). 01H : Data length 8bits, Odd Parity. Important Note: After termination, if motor does not move, please reset (3). 02H : Data length 8bits, Even Parity. by switching on and off the incoming power supply. to be continued.. ABtUS AVS-SSR8/2 ABtUS AVS-SSR8/2...

This manual is also suitable for:

Avs-ssr8/1