Advertisement

Quick Links

www.nausicaa-medical.com
NAUSICAA Medical is ISO 13485 certified
LIFT: BLUE EASYLEV 3 FIXED OR WITH
MECHANICAL OR ELECTRIC ECP
STEEL MANUFACTURE
MAXIMUM CAPACITY: 150 kg
CLASS 1 MEDICAL DEVICE
ALL OUR APPLIANCES COMPLY WITH THE NF EN ISO 10535 : 2021 STANDARD.
Installation Guide / Verticalizer: BLUE EASYLEV 3
Manufactured by NAUSICAA Médical S.A.S. / Approved by Ghizlane Labrosse (Biomedical Engineer)
V 02.07/22

Advertisement

Table of Contents
loading

Summary of Contents for NAUSICAA BLUE EASYLEV 3

  • Page 1 MAXIMUM CAPACITY: 150 kg CLASS 1 MEDICAL DEVICE ALL OUR APPLIANCES COMPLY WITH THE NF EN ISO 10535 : 2021 STANDARD. Installation Guide / Verticalizer: BLUE EASYLEV 3 Manufactured by NAUSICAA Médical S.A.S. / Approved by Ghizlane Labrosse (Biomedical Engineer) V 02.07/22...
  • Page 2: Table Of Contents

    • Technical and dimensional characteristics • Spare parts • Cleaning and maintenance • Technical data of the motorisation 24-25 • Troubleshooting guide • Guarantee Installation Guide / Verticalizer: BLUE EASYLEV 3 Manufactured by NAUSICAA Médical S.A.S. / Approved by Ghizlane Labrosse (Biomedical Engineer)
  • Page 3 This device has been designed for patients weighing up to 150 kg. The climatic conditions for the use of the BLUE EASYLEV 3 are as follows: ambient temperature of 0°C to 40°C, humidity of 20% to 80% and air pressure of 700 to 1060 hPa.
  • Page 4: Installation Instructions

    • THERE IS NO WEAR OR DEFORMATION ON THE HOOKS. Your lift is delivered assembled and ready to use. BLUE EASYLEV 3 FIXED EASYLEV 3 ECP MECHANICAL OR ELECTRIC Installation Guide / Verticalizer: BLUE EASYLEV 3 Manufactured by NAUSICAA Médical S.A.S. / Approved by Ghizlane Labrosse (Biomedical Engineer)
  • Page 5 • Never charge the batteries of a sit-to-stand lift near a bath or shower. Installation Guide / Verticalizer: BLUE EASYLEV 3 Manufactured by NAUSICAA Médical S.A.S. / Approved by Ghizlane Labrosse (Biomedical Engineer)
  • Page 6: Use Of The Device

    • How to use a sit-to-stand lift : - Patients with low muscle tone should be transferred to a semi-seated position. Installation Guide / Verticalizer: BLUE EASYLEV 3 Manufactured by NAUSICAA Médical S.A.S. / Approved by Ghizlane Labrosse (Biomedical Engineer)
  • Page 7 • In addition, the patient’s shins must be in contact with the knee support at all times. • The positioning of the knee support should be done by a caregiver. Installation Guide / Verticalizer: BLUE EASYLEV 3 Manufactured by NAUSICAA Médical S.A.S. / Approved by Ghizlane Labrosse (Biomedical Engineer)
  • Page 8 (The lift can tilt to the side). FIXED MODEL MECHANICAL AND ELECTRICAL ECP MODEL Small front wheel Large rear wheel Unbraked front Braked rear wheel wheel Installation Guide / Verticalizer: BLUE EASYLEV 3 Manufactured by NAUSICAA Médical S.A.S. / Approved by Ghizlane Labrosse (Biomedical Engineer)
  • Page 9 Check that the battery is charged by looking at the green indicator light when the battery is char- ged. -This is loaded. Installation Guide / Verticalizer: BLUE EASYLEV 3 Manufactured by NAUSICAA Médical S.A.S. / Approved by Ghizlane Labrosse (Biomedical Engineer)
  • Page 10 Remote control for electric mechanichal ECP ECP version Lowering the lifting Climbing lifting arm Opening of Closing the feet the feet Installation Guide / Verticalizer: BLUE EASYLEV 3 Manufactured by NAUSICAA Médical S.A.S. / Approved by Ghizlane Labrosse (Biomedical Engineer)
  • Page 11: Using The Strap

    • Before transferring a patient with the lift, make sure that the vest is securely attached to both hooks on the lift. Installation Guide / Verticalizer: BLUE EASYLEV 3 Manufactured by NAUSICAA Médical S.A.S. / Approved by Ghizlane Labrosse (Biomedical Engineer)
  • Page 12 • information about the condition of the support element; • the next scheduled check date; • the name, contact details and signature of the controller. Installation Guide / Verticalizer: BLUE EASYLEV 3 Manufactured by NAUSICAA Médical S.A.S. / Approved by Ghizlane Labrosse (Biomedical Engineer)
  • Page 13: Labelling

    The lift should be cleaned, disinfected and maintained after each use. Before reuse, refer to the chap- ters on : • Preventive Maintenance & Safety Checks • Cleaning & Maintenance Labelling Labelling on the carton Installation Guide / Verticalizer: BLUE EASYLEV 3 Manufactured by NAUSICAA Médical S.A.S. / Approved by Ghizlane Labrosse (Biomedical Engineer)
  • Page 14 (goupilles, clips ou boulons), et le bon serrage de la visserie (voir le manuel d’utilisation). NE PAS UTILISER L’APPAREIL EN CAS DE MANQUE OU DE MAUVAIS ETAT. NAUSICAA Médical - 12 Allée du Piot - ZA Pôle Actif - 30660 Gallargues-le-Montueux- FRANCE BATTERY MAINTENANCE A POORLY MAINTAINED BATTERY DETERIORATES •...
  • Page 15 Labelling Installation Guide / Verticalizer: BLUE EASYLEV 3 Manufactured by NAUSICAA Médical S.A.S. / Approved by Ghizlane Labrosse (Biomedical Engineer)
  • Page 16: Preventive Maintenance And Safety Checks

    Operation of the emergency stop Battery condition (charge retention) Remote control status Checks carried out on: Checks carried out by: Expected date of next inspection: Installation Guide / Verticalizer: BLUE EASYLEV 3 Manufactured by NAUSICAA Médical S.A.S. / Approved by Ghizlane Labrosse (Biomedical Engineer)
  • Page 17 Preventive Maintenance & Safety Checks Upper part common to all 3 models 12 et 13 Installation Guide / Verticalizer: BLUE EASYLEV 3 Manufactured by NAUSICAA Médical S.A.S. / Approved by Ghizlane Labrosse (Biomedical Engineer)
  • Page 18 Preventive Maintenance & Safety Checks Fixed foot (Behind the knee rest) 12 and 13 Mechanical ECP or electric 12 and 13 Installation Guide / Verticalizer: BLUE EASYLEV 3 Manufactured by NAUSICAA Médical S.A.S. / Approved by Ghizlane Labrosse (Biomedical Engineer)
  • Page 19 Periodic greasing: use a «3 in 1» product or similar Upper part common to all 3 models Fixed foot ECP mechanical or electrical Installation Guide / Verticalizer: BLUE EASYLEV 3 Manufactured by NAUSICAA Médical S.A.S. / Approved by Ghizlane Labrosse (Biomedical Engineer)
  • Page 20: General Safety Instructions

    19. If the lift is damaged or defective, it should no longer be used and should not be connected to the power supply. Inform the dealer and instruct him to remedy the defect or fault. 20. Any serious incident occurring in connection with the device should be reported to NAUSICAA MEDICAL and patient is established.
  • Page 21 G. Max. base width : H. Turning diameter: 89 cm • mechanical spacing: 81 cm • electrical spacing: 80 cm H. Turning diameter: 112 cm Installation Guide / Verticalizer: BLUE EASYLEV 3 Manufactured by NAUSICAA Médical S.A.S. / Approved by Ghizlane Labrosse (Biomedical Engineer)
  • Page 22: Spare Parts

    Service Department: Verticalizers & Lifts Telephone: 04 66 71 71 80 Fax: 04 66 71 71 81 Mail: sav@nausicaa-medical.com Installation Guide / Verticalizer: BLUE EASYLEV 3 Manufactured by NAUSICAA Médical S.A.S. / Approved by Ghizlane Labrosse (Biomedical Engineer)
  • Page 23: Cleaning And Maintenance

    If you notice a malfunction, contact the Service Department: Verticalizers & Lifts Telephone: 04 66 71 71 80 Fax: 04 66 71 71 81 Mail: sav@nausicaa-medical.com Installation Guide / Verticalizer: BLUE EASYLEV 3 Manufactured by NAUSICAA Médical S.A.S. / Approved by Ghizlane Labrosse (Biomedical Engineer)
  • Page 24 • Overload protection by thermal switches • Noise level of the cylinder: 60 dB at 1 metre • Electromagnetic compatibility: complies with EN 60601-1-2 Connection diagram Installation Guide / Verticalizer: BLUE EASYLEV 3 Manufactured by NAUSICAA Médical S.A.S. / Approved by Ghizlane Labrosse (Biomedical Engineer)
  • Page 25 / deactivate The light indica- tor flashes green twice and the housing green twice Installation Guide / Verticalizer: BLUE EASYLEV 3 Manufactured by NAUSICAA Médical S.A.S. / Approved by Ghizlane Labrosse (Biomedical Engineer)
  • Page 26: Troubleshooting Guide

    The cylinder no longer moves up or 2. The remote control is out of order. 2. Change the remote control. down. Installation Guide / Verticalizer: BLUE EASYLEV 3 Manufactured by NAUSICAA Médical S.A.S. / Approved by Ghizlane Labrosse (Biomedical Engineer)
  • Page 27: Guarantee

    Please note that defective spare parts must be returned to NAUSICAA Médical S.A.’s After Sales Ser- vice, otherwise they will be invoiced one month after the parts are sent by NAUSICAA Médical S.A.S. • Article 9: Defective parts changed under or outside of the guarantee will be guaranteed for 6 months from the date of repair or the sending of spare parts.
  • Page 28 Installation Guide / Verticalizer: BLUE EASYLEV 3 Manufactured by NAUSICAA Médical S.A.S. / Approved by Ghizlane Labrosse (Biomedical Engineer)
  • Page 32 Head Office Sales Department Telephone: 04 66 51 50 80 Fax: 04 66 51 50 47 Mail: contact@nausicaa-medical.com www.nausicaa-medical.com Your contact : Manufactured by NAUSICAA Médical S.A.S. 12 Allée du Piot - ZA Pôle Actif 30660 Gallargues le Montueux FRANCE...

This manual is also suitable for:

Blue easylev 3 fixedEasylev 3 ecp mechanicalEasylev 3 ecp electric

Table of Contents