Pixsys ITW410 User Manual
Pixsys ITW410 User Manual

Pixsys ITW410 User Manual

Graphic datalogger up to 16 zones
Table of Contents

Advertisement

Available languages

Available languages

Quick Links

ITW410 / 710
Graphic datalogger up to 16 zones /
Datalogger grafico fino a 16 zone
User manual / Manuale d'uso

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ITW410 and is the answer not in the manual?

Questions and answers

Summary of Contents for Pixsys ITW410

  • Page 1 ITW410 / 710 Graphic datalogger up to 16 zones / Datalogger grafico fino a 16 zone User manual / Manuale d’uso...
  • Page 3: Table Of Contents

    12.a Connection via FTP to Operator panel ......................14 12.b Access to operator panel's user interface in LAN network ................. 14 12.c Remote acess to the operator panel's user interface ................... 14 13 Software for ITW410/710 ............................15 13.1 Main synoptic .............................. 15 13.2 System configuration ..........................16 13.3 PROCESS CONFIG.
  • Page 4 12.a Connessione via FTP al pannello operatore ....................41 12.b Accesso all'interfaccia utente del pannello operatore in una rete interna ..........41 12.c Accesso all'interfaccia utente del pannello operatore da remoto ............41 13 Il software per applicativo ITW410/710 ........................ 42 13.1 Sinottico principale ............................ 42 13.2 Configurazioni del sistema ........................
  • Page 5: Introduction

    Introduction ITW kit is a data logging and supervision system managing 1 to 8 analogue signals in the ITW410-AD (4”) and 1 to 16 analogue signals in the ITW710-AD (7”). It can be configured with different types of sensors (PT100, Thermocouples, NTC, PTC, humidity, pressure, level transducers with linear signals 4..20mA/0..10V).
  • Page 6: Installation Guidelines

    Environmental policy/WEEE international regulations. The same applies for all other devices connected to the system, such as drives. All tasks such as the installation, commissioning and servicing of devices are only permitted Do not dispose electric tools together with household waste material. to be carried out by qualified personnel.
  • Page 7: Mcm260X

    MCM260X Wiring connections This device has been designed and manufactured in conformity to Low Voltage Directive 2006/95/EC, MCM260X 2014/35/EU (LVD) and EMC Directive 2004/108/EC, 2014/30/EU (EMC). For installation into industrial 72 mm 64 mm environments please observe following safety guidelines: •...
  • Page 8: Using Rs485/Com2 On Terminal M1

    Using RS485/COM2 on terminal M1 CANH (B) Fieldbus: 13: CANH / (B) RS485+ RS485 14: CANL / (A) RS485- CANL (A) 15: (C) GND per CANbus e Modbus RTU RS485 Modbus RTU Master communication: Shield / Schermo PIN3: B+ (blue) PIN4: A- (white) PIN5: GND (brown) Digital I/O module “MCM260X-1AD”...
  • Page 9: Usb Interface

    It is suggested to replace the battery every 3 years. When battery is removed, an internal number of USB devices available on the market, Pixsys cannot guarantee their performance. dedicated device allows replacement without data loss if operation is completed within 1 hour since...
  • Page 10: Access To System Through Ethernet Port

    "Pixsys Portal" service. Once the VPN connection has been established through accessed. the "Pixsys Portal" service, access to the panel can be performed exactly as described in the previous The individual zone window shows the parameter.
  • Page 11: System Configuration

    13.2 System configuration 13.3 PROCESS CONFIG. System configuration implies to parametrize the following aspects: - Configuration of the related zones of the MCM260X-5AD I/O module - Configuration of the alarm outputs of the MCM260X-1AD I/O module - Configuration of the system date and time - Configuration of the data logger (sampling time, file name) This window allows to set analogue - Load/save configurations...
  • Page 12 • Sensor type • Potentiometer value It identifies the type of sensor connected to the I/O module. It selects the value of the potentiometer connected on Alarm Analogue input configuration / sensor selection: 1..150 kOhm. Default: 10kOhm Disabled (Default) Tc-K -260 °C..1360 °C By pressing "Restore to default", the Tc-S...
  • Page 13: Alarms Config

    • Maximum duration of AI sampling deviation • Alarm name It determines the maximum duration for which sampling of the analogue input can be discarded if It gives a name to the alarm (this name will be displayed on the alarm page if the Message “Action” has considered unacceptable (see parameter "Maximum difference for new AI sampling").
  • Page 14: Absolute Alarm Or Threshold Alarm Active Below

    13.5.b Absolute alarm or threshold alarm active below 10..3600 seconds, Default: 10 Hysteresis parameter • File name  > 0 It sets the file name to be created in the device's internal memory with extension 'csv'. Alarm Spv Absolute alarm. Hysteresis value greater than “0”. By pressing "Export records to USB key", you can export all csv files of recordings Time...
  • Page 15: Advanced

    Reboot SYSTEM NB: If the access password changes It executes a restart of the entire system. and is no longer available, operator panel must be returned to Pixsys via 15.2 DEVICES DIAGNOSTIC RMA procedure. The panel will be restored to factory conditions losing all configurations.
  • Page 16: Remote Access

    LANGUAGE CHANGE may be causing loss of communication between the operator panel and the device. • Lost packets It shows lost packets counter (no communication) of the module. If counter continues to increase, verify previous step or replace device if necessary. To change language, press "Language"...
  • Page 17 Warranty terms Pixsys srl warrants its electronic devices for 12 months from Invoice date. Pixsys liability shall be limited to repairing (or replacing at its option) any defective product which is returned with RMA (Return Material Authorization) priorly obtained on Pixsys website and to be clearly marked on documents.
  • Page 18 30 - KTD710/820 - User manual...
  • Page 19: Introduzione

    Il kit ITW è un sistema di registrazione e monitoraggio dati che può gestire da 1 a 8 segnali analogici per il modello ITW410 (4") e da 1 a 16 segnali analogici per il modello ITW710 (7”). È configurabile con differenti tipi di sonde (PT100, Termocoppie, NTC, PTC, trasduttori di umidità, pressione, livello con segnali analogici 4..20mA/0..10V) e può...
  • Page 20: Norme Di Sicurezza

    Norme di sicurezza Organizzazione delle note di sicurezza Le indicazioni di questo manuale sono riferite a prodotti Pixsys quali i dispositivi logici programmabili Le note sulla sicurezza in questo manuale sono organizzate come segue: (PLC) e i dispositivi di controllo e monitoraggio (PC industriali, HMI) da ora in poi identificati Note di sicurezza Descrizione semplicemente con il termine “Il dispositivo”...
  • Page 21: Dimensione E Installazione

    RS485 Modbus RTU su Seriale di RS485 Modbus RTU su RS485 Modbus RTU su morsettiera o connettore comunicazione morsettiera. morsettiera. DB9. RS485 Modbus Galvanicamente isolata. Galvanicamente isolata. Galvanicamente isolata. 34 - ITW410/710 - Manuale d’uso Manuale d’uso - ITW410/710 - 35...
  • Page 22: Collegamenti Elettrici

    CANH / (B) RS485+ RS485 4: A- Modbus RTU CANL / (A) RS485- CANL (A) 5: GND Modbus RTU (C) GND per CANbus e Modbus RTU Shield / Schermo 36 - ITW410/710 - Manuale d’uso Manuale d’uso - ITW410/710 - 37...
  • Page 23: Modulo Uscite "Mcm260X-1Ad

    Differenti dispositivi USB possono essere collegati alle interfacce USB su questo dispositivo. • 2: -VDC – A causa dell'elevato numero di dispositivi USB disponibili sul mercato, Pixsys non può garantire le Alimentazione della sola parte logica del dispositivo. Se la tensione +VDC è loro performance. + VDC portata al morsetto 3 e non al morsetto 1, le uscite non sono attive.
  • Page 24: Configurazione Dei Moduli I/O Mcm260X Per La Comunicazione Modbus

    LAN aziendale. Per la modalità - TerM (Stato resistenza di terminazione di linea): “120” solo nell'ultimo nodo della rete diaccesso remoto, si rimanda al manaule specifico del serivizio “Pixsys Portal“. Una volta instaurata la - Old.C (Modalità compatibilità): “no.L.L”.
  • Page 25: Il Software Per Applicativo Itw410/710

    “Logout“, 3) spegnere e riaccendere il terminale. NB: Dopo aver effettuato l'acceso come installatore, nella pagina AVANZATE è possibile cambiare la password di accesso con una a piacere (massimo 4 cifre). 42 - ITW410/710 - Manuale d’uso Manuale d’uso - ITW410/710 - 43...
  • Page 26: Config. Processi

    4 mA. Il valore può essere superiore a quello inserito nel parametro seguente. -32767..+32767 Default: 0. • Limite superiore ingresso Limite superiore dell’ingresso analogico AI1 solo per normalizzati. Es: con ingresso 4..20 mA questo 44 - ITW410/710 - Manuale d’uso Manuale d’uso - ITW410/710 - 45...
  • Page 27: Config. Allarmi

    Disab (Default) °C Nella schermata CONFIG. ALLARMI °F sono visualizzati i pulsanti di inH2O configurazione degli allarmi. inHg gala mmHg mH2O mBar ppmv ppmw mmH20 m3/s m3/m m3/h kg/h 46 - ITW410/710 - Manuale d’uso Manuale d’uso - ITW410/710 - 47...
  • Page 28: Configurazione Allarme

    • Ritardo di attivazione Ritardo allarme. Ritardo in fase di entrata nello stato di allarme 48 - ITW410/710 - Manuale d’uso Manuale d’uso - ITW410/710 - 49...
  • Page 29: Config. Datalogger

    USB formattata in FAT 32. Premendo il pulsante "Elimina file delle registrazioni dalla memoria interna" si esegue l'eliminazione di tutti i file di registrazione salvati internamente nel percorso "NandFlash\Records". 50 - ITW410/710 - Manuale d’uso Manuale d’uso - ITW410/710 - 51...
  • Page 30: Avanzate

    Mostra il contatore dei pacchetti persi (mancate comunicazioni) del moduloa. In caso il contatore continui ad incrementare, effettuare le verifiche del punto precedente o eventualmente sostituire il dispositivo. 52 - ITW410/710 - Manuale d’uso Manuale d’uso - ITW410/710 - 53...
  • Page 31: Accesso Remoto

    - Tutti: visualizza l'intera registrazione. - Minuto: visualizza i campionamenti dell'ultimo minuto, è possibile spostarsi di un minuto avanti/ 54 - ITW410/710 - Manuale d’uso Manuale d’uso - ITW410/710 - 55...
  • Page 32 Eventuali Agendo sul pulsante “Gestione file delle registrazioni” si apre un finestra in cui è possibile gestire i file di interventi di assistenza da parte di Pixsys per il ripristino di sistema operativo o programmi saranno registrazione effettuati: soggetti alla tariffa di assistenza vigente.
  • Page 33 58 - ITW410/710 - Manuale d’uso...
  • Page 35 Prima di utilizzare il dispositivo leggere con attenzione le informazioni di sicurezza e settaggio contenute in questo manuale. Prog. Cntlr E498498 PIXSYS s.r.l. www.pixsys.net sales@pixsys.net - support@pixsys.net online assistance: http://forum.pixsys.net via Po, 16 I-30030 Mellaredo di Pianiga, VENEZIA (IT) Tel +39 041 5190518 2300.10.350-RevA...

Table of Contents