2.2.1.1 XG System bulk dump
This message sets the XG SYSTEM block (refer to tables <1 -1>, <1 - 2>).
2.2.1.2 Multi Effect1 bulk dump
This message sets the MULTI EFFECT1 block (refer to tables <1 - 1>, <1 -
3>).
2.2.1.3 Multi EQ bulk dump
This message sets the MULTI EQ block (refer to tables <1 - 1>, <1 - 4>).
2.2.1.4 Multi Effect2 bulk dump
This message sets the MULTI EFFECT2 block (refer to tables <1 - 1>, <1 -
5>).
2.2.1.5 Multi Part bulk dump
This message sets the MULTI PART block (refer to tables <1 - 1>, <1 - 6>).
2.2.1.6 Audio Part bulk dump
This message sets the Audio PART block (refer to tables <1 - 1>, <1 - 7>).
2.2.1.7 Drums Setup bulk dump
This message sets the DRUMS SETUP block (refer to tables <1 - 1>, <1 -
9>).
2.2.2 SW1000XG native bulk dump
This message modifies parameters unique to the SW1000XG. Unlike param-
eter change messages, a single message will modify multiple parameters.
11110000
F0H
Exclusive status
01000011
43H
YAMAHA ID
0000nnnn
0NH
N:Device Number
01001001
49H
Model ID
0sssssss
SSH
ByteCountMSB
0ttttttt
TTH
ByteCountLSB
0ggggggg
GGH
Address High
0mmmmmmm
MMH
Address Mid
0lllllll
LLH
Address Low
0vvvvvvv
VVH
Data
:
:
0kkkkkkk
KKH
Check-sum
11110111
F7H
End of Exclusive
Details are the same as for 2.2.1 XG Bulk Dump. However, refer to table 2-n
for the address, byte count, and block.
2.2.2.1 System bulk dump
This message sets the SYSTEM block (refer to tables <2 - 1>, <2 - 2>).
3. Realtime messages
3.1 Active sensing
a) Transmission
not transmitted.
b) Reception
Once FE has been received, failure to receive any MIDI message for an
interval longer than approximately 300 msec will cause processing to be
performed as if ALL SOUND OFF, ALL NOTE OFF, and RESET ALL
CONTROLLERS messages were received, and the unit will reset to a
condition in which FE was never received.