Page 4
oxide Sulfur 0-20 0.01 ±3F.s dioxide 1.1 System parameters paramet range System 12-24V power supply RS485 communi cation Operatin -40-70℃ temperat Working 0-95%RH humidity condensation...
Page 5
1.1 System framework diagram Chapter 1 Hardware Connection 1.1 Inspection before equipment installation Please check the equipment list before installing the equipment:...
1.1 Interface description The power interface is a wide-voltage power input that can be 12-24V. When wiring the 485 signal line, pay attention to the A/B two lines can not be reversed, and the address of multiple set devices on the bus can not conflict.
Page 7
Thre Description colo Power is positive(12- 24VDC) supp blac Power negative yell 485-A icati Blue 485-B...
Page 8
The factory default provides 0.6 meters long wire, customers can extend the wire as needed or wire in order. 1.1 Installation matters The equipment is fixed by three mounting screws at the bottom. Customers can use screws to fix the louver equipment. The fixing holes are located as shown in the figure below.
Page 9
At the same time, please pay attention to the following precautions: 1. Avoid installing in areas that are easy to transfer heat and will directly cause a temperature difference with the area to be measured, otherwise the temperature and humidity measurement will be inaccurate.
Page 10
After connecting the sensor to the computer through USB to 485 and supplying power, you can see the correct COM port in the computer (check the COM port in "My Computer — Properties—Device Manager—Port"). As shown in the figure above, your serial port...
Page 11
485 bus . Please note that you need to ensure that there is only one sensor on the 485 bus when using the software to automatically obtain it.
pressure sensor for atmospheric pressure sensor ", the illuminance sensor selects "illuminance 20W", Oxygen sensor selects "Oxygen Transmitter", other sensors select the default "No other sensor". 1.1 ID1.1 Modify the baud rate and device ID When the device is disconnected, click the device baud rate and set address in the communication settings to complete the related settings.
Page 13
Address code = 1 byte Function code = 1 byte Data area = N bytes Error check = 16-bit CRC code Time to end structure ≥ 4 bytes Address code: It is the function indicator of the transmitter. This transmitter only uses the function code 0x03 (read register data).
The host polling interval and waiting time for response are too short, and both need to be set above 200ms. ⚫ The 485 bus is disconnected, or the A and B wires are connected reversely. ⚫ There are too many devices or the wiring is too long.
Page 16
You should supply power nearby, add a 485 booster, and add a 120Ω terminal resistance. ⚫ USB to 485 driver is not installed or damaged ⚫ Equipment damage 1.2 Warranty and after-sales The warranty clauses follow the sensor after-sales clauses of Weihai Jingxun Changtong Electronic Technology Co., Ltd.,...