Download Print this page

jablotron JA-162PB Manual page 2

Wireless combined pir motion and glass-break detector

Advertisement

JA-162PB, JA-162PB-GR, JA-162PB-AN Wireless combined PIR
TYPE: 5PIRGBS2202OQ
Sensor of tearing-off from the wall: turns on/off the monitoring
of an optional additional tamper contact on a JA-191PL joint holder.
Detection characteristics
The standard lens that is supplied with the JA-162PB detector covers
an area of 90 degrees /12 m– see the following figure 3.
Figure 3: Detection characteristics of PIR detector
Fig 4: Detection characteristics of the GBS sensor.
Detector with a white lens (JA-162PB) offers standard protection
against white light as required by regulation (up to 6000 Lux).
Detector with a grey (JA-162PB-GR) and black (JA-162PB-AN) lens
offer increased protection against white light, well above the limits
given by regulation (up to 10000 Lux).
Note: when utilizing an alternative lens, test whether the detector
covers the area correctly (an incorrectly installed lens can cause
detection errors).
Detector testing
While in service mode, the detector indicates each activation with
its LED indicator. Once service mode is exited, the device enters
normal operation. During normal operation, LED indication is off,
including fault indication – yellow LED indication. Each activation
may be viewed within the F-Link software, within the Diagnostics
tab.
Battery replacement
The control panel automatically detects and reports low battery
status. We recommend replacing the batteries within two weeks of
the low battery status being reported. The batteries should be
replaced by a service technician while the control panel is in Service
mode. Always replace both batteries!
After battery removal, it is necessary to wait for at least 10 s or
close the detector without batteries before replacing them (this will
activate the tamper contact (12) and discharge the remaining
energy).
Notes:
If you insert an discharged battery, the detector immediately
detects it and starts indicating low battery status during the
stabilization period (at least 15 s).
The battery status can be monitored in the Diagnostics tab in
the F-Link software.
In order to make sure the detector works correctly, we
recommend using the batteries supplied by a distributor (BAT-
3V0-CR123A) or other quality lithium batteries.
Do not discard the battery into the trash; dispose of it at a waste
collection point.
JA-162PB, JA-162PB-GR, JA-162PB-AN
motion and glass-break detector
Technical parameters
Power
Typical battery lifetime
Low battery voltage
Quiescent current consumption
Maximal current consumption
Communication band
Maximum radio-frequency power (ERP)
RF range
Recommended installation height
PIR detection angle/range
GBS detection angle/range
Dimensions
Weight (w/o batteries)
Classification
Environment
Operating temperature range
Average operational humidity
Certification body
In compliance with
ETSI EN 300 220-1,2, EN 50130-4, EN 55032,
EN IEC 62368-1, EN IEC 63000, EN 50131-1, EN 50131-2-2,
Can be operated according to
Recommended screw
JABLOTRON ALARMS a.s. hereby declares that product
5PIRGBS2202OQ is in a compliance with the relevant
European Union harmonisation legislation: Directives No:
2014/35/EU, 2014/30/EU, 2011/65/EU. The original of the
conformity assessment can be found at www.jablotron.com –
the Downloads section.
Note: Disposing of this product correctly will help save
valuable resources and prevent any potential negative effects
on human health and the environment, which could otherwise
arise from inappropriate waste handling. Please return the
product to the dealer or contact your local authority for further
details of your nearest designated collection point.
2 / 2
2x Lithium battery CR123A (3.0 V/1.5 Ah)
Please note: Batteries are not included.
approx. 3 years
868.1 MHz, protocol JABLOTRON
500 m (open area)
2.5 m above the floor
150 x 63 x 40 mm
Security grade 2/Environmental class II
(According to EN 50131-1)
indoor general
-10 °C to +40 °C
75% RH, w/o condensation
Trezor Test s.r.o. (no. 3025)
EN 50131-2-7-1, EN 50131-5-3, EN 50131-6.
ERC REC 70-03
2 x
ø 3.5 x 40 mm (countersunk head)
MOQ51702
<2.7 V
50 uA
50 mA
<25 mW
90°/12 m
90°/9 m
135 g

Advertisement

loading

This manual is also suitable for:

Ja-162pb-grJa-162pb-an