Hide thumbs Also See for Urfeuer 50/88:

Advertisement

Quick Links

User
Guide
Urfeuer 50/88
©2021

Advertisement

Table of Contents
loading

Summary of Contents for Brunner Urfeuer 50/88

  • Page 1 User Guide Urfeuer 50/88 ©2021...
  • Page 2: Table Of Contents

    Please observe the necessary national and European standards and local regulations. Please observe the fire regulations of your country. In case of doubt, check the valid conditions for the operation of fireplaces in your local area. Subject to technical changes! (1.7) © 2021 Brunner GmbH...
  • Page 3: Basics

    7 B 10342/91, OVG Rheinland-Pfalz from 30.11.1993, 7 A 12014/92). Depending on location, its use can be allowed with fur- ther limitations or more often. The Urfeuer fireplaces are tested and approved according to EN 13229 (EN 16510 Part 2). © 2021 Brunner GmbH (1.7)
  • Page 4: Precautionary Statements

    Structural means for combustion air supply cannot be modified. Functionality must be ensured by regular checks. Allowable fuels Please use only fuels of quality and quantity described in this manual. Other fuels are not allowed. (1.7) © 2021 Brunner GmbH...
  • Page 5 A much greater distance must be kept from fireplace surfaces made of metal. Prohibited fuels Never use petrol or alcohol as aids for lighting fire! Not suitable fuel types, qualities or amounts can lead to dam- ages. © 2021 Brunner GmbH (1.7)
  • Page 6 Spilling out embers To prevent spilling out of embers, use the provided protection strip when the Urfeuer fireplace is in use. The fireplace can be used only under supervision! (1.7) © 2021 Brunner GmbH...
  • Page 7: Firewood And Heating Power

    Natural firewood (left) is the best fuel for fireplaces, but you can use also wood briquettes according to DIN 17225-3, Class A1, length >14 cm (5.51 in), diameter >8 cm (3.15 in) (right). © 2021 Brunner GmbH (1.7)
  • Page 8 Adjusting the heat by reducing the volume of combustion air is wrong! If there is not enough combustion air available, the energy contained in fire- wood cannot be completely released. At the same time, the emissions are rising due to unburned particles. (1.7) © 2021 Brunner GmbH...
  • Page 9 User Guide. Unsuitable, not recommended fuels are not allowed to be burned in a fireplace. Loading of fire wood Load volume Log length Log circumfer- ence Urfeuer 50/88 2,0 kg - 4,0 25 cm - 50 cm 20 cm - 30 cm © 2021 Brunner GmbH (1.7)
  • Page 10: Instructions For Use

    Softwood species (conifers) have a closed-cell structure which is bursting during combustion, causing sparks and glowing embers to be thrown out of the fireplace. In these cases, the integrated spark mesh should be pulled down. Hardwood is usually burning more calm and evenly. (1.7) © 2021 Brunner GmbH...
  • Page 11 Firewood is placed crosswise at the rear wall in center of the Urfeuer fire- place (see picture). With a fire starter placed underneath (e.g. BRUNNER Fidibus), the fire will advance very quickly. During reloading, the wood logs must not be laid very close to the edge of the combustion chamber opening, but on the existing area of glowing embers.
  • Page 12: Ember Retaining Strip

    EMBER RETAINING STRIP D019061 (1.7) © 2021 Brunner GmbH...
  • Page 13: Shut-Off Flap Operation

    Attach the operating aid.. Shut-off flap in closed position. Close the shut- off flap only af- ter a finished combustion! Shut-off flap in open po- sition. Keep the shut- off flap open during combus- tion! © 2021 Brunner GmbH (1.7)
  • Page 14: Closing Spark Protection Mesh

    CLOSING SPARK PROTECTION MESH To prevent the glowing embers from falling out, keep the spark protection mesh closed during combustion! Im. 1: Spark mesh (1.7) © 2021 Brunner GmbH...
  • Page 15: Note

    The warranty expires if the device has not been used as intended. Intend- ed use includes reading and following the instructions of this User Guide. It is necessary to follow any other relevant instructions, like the “Operating instructions for tiled stove water boilers”! My stove fitting company: © 2021 Brunner GmbH (1.7)
  • Page 16: Disposal

    Technical and assortment changes as well as errors and Zellhuber Ring 17-18 misprints reserved. Reprinting and reproduction, even in part, only with D-84307 Eggenfelden the express permission of the publisher. Tel.: +49 (0) 8721/771-0 / Fax: +49 (0) 8721/771-100 Email: info@brunner.de Art.Nr.: 200238 (1.7) © 2021 Brunner GmbH...

Table of Contents