Fireplaces equipped with a water boiler must be pressure-tested after hydraulic connection to the heating system. Masonry work may follow only after this pressure test. Ulrich Brunner GmbH does not cover any costs incurred by necessary dismantling of masonry for rework at water boiler installation or replacement of the boiler.
If additional parts are installed on the fireplace which are not approved for this appliance by Ulrich Brunner GmbH (for example, an external control unit), it is a customized product that meets cus- tomer requirements. The resulting fireplace insert is not type-tested; the declaration of performance of this fireplace insert will be no longer valid.
Combustion air ducts Stoves and fireplaces with BRUNNER heating inserts are classified by law as indoor air-dependent fire- places. The combustion air can be supplied from outside via a sufficiently dimensioned pipework. This for BRUN- NER heating inserts are fitted with a combustion air connection piece.
Page 27
Dimension sheets - Kompakt-Kessel B4 We suggest for CAD planning Palette CAD. Permanent updated drawings: www.brunner.de Frames/ flue gas outlet connection/ combustion air supply connection/ front variants/ support bearing are marked in col- Stand: 2023-09-11...
Page 28
Planning and installation - Kompakt-Kessel B4 Tested according to EN 13229 W EN 13229 W Values measured at Rated power Practical avg. Data for functional demonstration Rated heat power 14.5 Room heating power Water heating power Fire wood volume kg/h Combustion performance 16.5 Flue gas mass flow...
Page 31
Dimension sheets - Kompakt-Kessel B7 Design characteristics for adjacent storage mass We suggest for CAD planning Palette CAD. Permanent updated drawings: www.brunner.de Frames/ flue gas outlet connection/ combustion air supply connection/ front variants/ support bearing are marked in col- Stand: 2023-09-11...
Page 32
Planning and installation - Kompakt-Kessel B7 Tested according to EN 13229 W EN 13229 W Values measured at Rated power Practical avg. Data for functional demonstration Rated heat power Fire wood volume kg/h Combustion performance Flue gas mass flow 10.9 17.9 Outlet temperature (before reheating surface) °C...
Page 35
Dimension sheets - Kompakt-Kessel B8 We suggest for CAD planning Palette CAD. Permanent updated drawings: www.brunner.de Frames/ flue gas outlet connection/ combustion air supply connection/ front variants/ support bearing are marked in col- Stand: 2023-09-11...
Page 36
Planning and installation - Kompakt-Kessel B8 Tested according to EN 13229 W EN 13229 W Values measured at Rated power Practical avg. Data for functional demonstration Rated heat power Fire wood volume kg/h Combustion performance 15.8 22.5 Flue gas mass flow 11.3 18.9 Outlet temperature (before reheating surface)