LOB-GW-DINRAIL-HYB-WMBUS
Wireless M-Bus NB-IoT Gateway with external power supply.
Model
LOB-GW-DINRAIL-HYB-WMBUS
Order number
8000157 - Wireless M-Bus Gateway (ext. Power, Din-Rail)
8000158 - Wireless M-Bus Gateway (ext. Power, 230V)
8000157 - Wireless M-Bus Gateway (ext. Power, Din-Rail)
Including: Antenna
Table of Content
Table of Content
8000158 - Wireless M-Bus Gateway (ext. Power, 230V)
Including: Antenna, 1x cable feedthrough

Advertisement

Table of Contents
loading

Summary of Contents for Lobaro LOB-GW-DINRAIL-HYB-WMBUS

  • Page 1: Table Of Contents

    Basic work cycle Quick start guide Compatible meters Setting up the device Interfaces Mobile operator and LTE band configuration Configuration Connection Parameters LoRaWAN Parameters NB-IoT Parameters Metering reception Parameters Modes of operation (work cycle) Deduplication Mobile data consumption The Lobaro Platform...
  • Page 2: Overview

    (Narrowband IoT) onto the Internet. Metering data is send to the Lobaro Platform, were it gets parsed, displayed and made available for further processing. Because most Wireless M-Bus telegrams are encrypted, the Platform allows adding decryption keys for individual meters, so that the data can be decrypted by the Platform.
  • Page 3 Vin - Supply voltage 12 - 24 Volt DC GND - Ground Vout - same as Vin NC - not connected NC - not connected GND - Ground Connected cables must be between 0.05 mm² (AWG30) and 1.31 mm² (AWG16). Inserted cable length must be between 6mm and 7mm.
  • Page 4 Config Port The config port can only be reached when the cover is removed The configuration port is compatible with our 6-pin Lobaro USB Configuration Adapter (Arcticle Nr. 8000005). A free to use configuration tool can be downloaded from the...
  • Page 5: Mobile Operator And Lte Band Configuration

    LTE / NB-IoT Networks Configuration The device is shipped with default configuration parameters. The configuration can be changed via the 6-pin config port using the Lobaro USB Configuration Adapter. More information about the usage of the configuration tools can be found in o ur documentation Remote Configuration is also supported after initial network connection.
  • Page 6: Metering Reception Parameters

    The NB-IoT functionality is enabled if the parameter is set to "lte". A SIM-Card has to inserted. Name Description Default Value Value Description & Examples Hostname / IP of the Lobaro Platform API Host 94.130.20.37 94.130.20.37 = backend.lobaro.com DNS is not supported yet...
  • Page 7: Modes Of Operation (Work Cycle)

    typFilter meter device type filter e.g. for Heat Cost and Water 08,07 (Comma blank= no filter, not used for xmode (Sensus RF) separated list WITHOUT spaces) "Other", "Oil", "Electricity", "Gas", "Heat", "Steam", "Warm Water", // 30 - 90°C "Water", "Heat Cost", "Compressed Air",...
  • Page 8: Deduplication

    – Log in with the credentials provided by Lobaro. Your Gateways should be listed under "Devices". If you have multiple devices in your account, you can distinguish them by the field "Address". The Address is printed on the box of the Gateway (the Address is the IMEI of the modem used by the device; that is the unique hardware address used for mobile communication).