Radiation Source Container FQG61/FQG62
Orientation of the fireproof
version
!
!
Endress+Hauser
Orientation A (recommended)
The source container is mounted with the compensation compartment on the top. In case of fire only the
emission channel will be closed by the liquefied lead.
Note!
After a fire, the screening is slightly reduced in the upper area of the container.
1
1: Level measurement; 2: Level limit detection
Orientation B (only if orientation A is impossible due to lack of space)
The source container is mounted with the compensation compartment at the bottom or in lateral position. In
case of fire the emission channel and the compensation compartment will be filled with the liquefied lead.
Note!
After a fire, the screening will be strongly reduced in the upper area of the source container.
1
1: Level measurement; 2: Level limit detection
2
2
L00-FQG6xxx-11-07-00-xx-005
L00-FQG6xxx-11-07-00-xx-006