Getting to know your device
Humans spend a large proportion of their time indoors. The air indoors is often polluted with dust particles, pollen, animal hair, odours, harmful gases as well as various bacteria and viruses. The LR 210 air cleaner cleans the ambient air using a three-layered filter system and an additional integrated ioniser.
The LR 210 air cleaner
- Filters air with a combi filter (activated carbon filter against harmful gases and unpleasant odours,HEPA filter H 13 against particles such as bacteria, viruses, mites, pollen and fine dust)
- Has a selectable ioniser
- Operates quietly with three output levels
- Has a timer function (two, four or eight hours)
- Has a sleep mode
- Is suitable for rooms from 10 m² 1) - 26 m² 2), in size,
- Energy-saving
- Switches off automatically when the housing cover is removed.
1) (ANSI/AHAM AC-1 2015)
2) (NRCC 54013-2011)
Principle of air cleaning
- The air cleaner's fan sucks in the contaminated air.
- The pre-filter filters out larger particles such as dust, dirt and hairs.
- Next, the activated carbon filter filters formaldehyde, benzene and other poisonous gases and unpleasant odours out of the ambient air.
- The HEPA filter then filters out small particles such as pollen, bacteria or viruses.
- The ioniser releases ions into the air. These negative ions bind the smallest particles to themselves due to the pull of the electric charge. Due to this higher concentration and the formation of larger particles, the particles are then collected in the ioniser collector or land on the floor, where they can be vacuumed up.
- The cleaned air is emitted via the air outlet on top of the air cleaner into the ambient air.
The HEPA H 13 filter has a filter performance of ≥ 99.95%. That means that 99.95% of particles (e.g. bacteria, viruses and fine dust) can be filtered out.
Contaminated, unfiltered air can have the following effects:
- Infections and respiratory diseases are more likely to occur
- Damage to health through harmful gases
Included in delivery
- 1x air purifier
- 1x combi filter (activated carbon/HEPA filter class H 13)
- 1x pre-filter
- 1 x set of instructions for use
Signs and symbols
| WARNING Warning instruction indicating a risk of injury or damage to health |
| IMPORTANT Safety note indicating possible damage to the device/accessory |
| Product information Note on important information |
The following symbols appear in these instructions for use:
Intended use
This air cleaner is intended exclusively for cleaning the air indoors. The device is intended for private use.
![]()
If you suffer from severe respiratory or lung disease, consult your doctor before using the air cleaner. This device must only be used for the purpose for which it was designed and in the manner specified in the instructions for use. Improper use can be dangerous. The manufacturer is not liable for damage resulting from improper or careless use.
Device description
|
- Air outlet
| - Housing cover
|
- Combi filter (activated carbon filter/HEPA filter H 13)
Activated carbon filter: To counter harmful gases and unpleasant smells HEPA filter H 13: Filters particles such as bacteria, viruses, mites, pollen and fine dust | - Housing
|
- Pre-filter
Filters coarse dust and dirt, such as hairs | - Air inlet
|
- Control panel
| |
|
- ON/OFF button
![]() Switches the device on/off If the light below "Filter reset" is flashing, change the filter. After changing the filter, hold down the on/off button to reset the filter change display. | - Ioniser/Sleep mode
![]() Switching the ioniser or night mode on/off.. |
- FAN SPEED button
![]() The air cleaner has three fan speeds: I (low), II (medium) and III (high). | - TIMER button
![]() The air cleaner features a timer function that you can use to determine the number of hours the air cleaner should run for before it automatically switches itself off. The air cleaner has three timer periods: 2H (two hours), 4H (four hours) and 8H (eight hours). |
Initial use
Removing the device
- Open the cardboard packaging.
- Remove the device from the top of the box without opening the film bag.
- Now remove all plastic films. Remove the combi filter from the device (see "Filter change" section) and take it out of the plastic film. Then re-insert the combi filter into the device.
- Check the device, mains plug and cable for damage.
Setting up the device
![]()
- Place the air cleaner on a firm, level surface to prevent vibrations and noise.
If you wish to reposition the air cleaner, only carry it by the handle on the rear of the device. - Set up the air cleaner in such a way that there is at least 30 cm clearance on all sides.
- Make sure that the air inlet and air outlet are never blocked.
Usage
Switching on the unit
- Always follow the instructions in chapter "Initial use".
- Insert the mains plug into the socket. Ensure that the cable does not pose a trip hazard.
- Press the ON/OFF button (
) to switch on the air cleaner.
Note
When starting up for the first time, all of the LEDs initially light up. The air cleaner is then set to the lowest fan speed and the ioniser is activated.
Note
If the "Filter reset" light above the on/off button is flashing, you must replace the combi filter. To do this, follow the instructions in the "Filter change" section.
Fan speed
The air cleaner has three fan speeds: I (low), II (medium) and III (high).
- To switch between the individual fan speeds, press the fan speed button
. The fan speed that is currently set lights up on the control panel.
Ioniser/Sleep mode
| Ioniser | Sleep mode | Note |
1 x press | ON | OFF | „ION" LED illuminates |
2 x press | ON | ON | „ION" LED illuminates „Sleep" LED flashes |
3 x press | OFF | ON | „ION" LED goes out „Sleep" LED flashes |
4 x press | OFF | OFF | „Sleep" LED goes out |
If sleep mode is activated, all the LEDs in the operating panel automatically switch off after 10 seconds. To deactivate sleep mode, press any button on the operating panel.
Timer function
The air cleaner features a timer function that you can use to determine the number of hours the air cleaner should run for before it automatically switches itself off. The air cleaner has three timer periods: 2H (two hours), 4H (four hours) and 8H (eight hours).
- To switch between the individual timer periods, press the TIMER button (
) The TIMER period that is currently set lights up on the control panel. The air cleaner will now automatically switch off after the set number of hours has passed. - To switch off the timer, repeatedly press the TIMER button (
), until the light above the TIMER button goes out. The air cleaner will now clean for an unlimited period.
Filter change
The three-layered filter should be replaced with a new one after 4320 operating hours. After 4320 operating hours, the red „Filter reset" LED flashes above the on/off button. To change the filter, proceed as follows:
- Press the ON/OFF button to switch off the air cleaner, and unplug it from the socket.
![]() | - Remove the housing cover as shown (magnetic fastening). First detach the magnetic fastening at the top, and then at the bottom.
![]() |
- Pull out the pre-filter. Now, to pull out the combi filter, pull carefully on the side tabs.
![]() | - Insert a new combi filter. To insert the combi filter correctly, align it with the tabs as shown. Position the pre-filter above it.
![]() |
- Re-insert the housing cover as shown until you see and hear it click into place (magnetic fastening). First attach the magnetic fastening at the bottom, and then at the top.
| - Insert the mains plug into the socket. Ensure that the cable does not pose a trip hazard. Press and hold the on/off button (
) for five seconds. The operating hours counter now resets to 0. ![]() |
If you wish to change the combi filter at specific personal intervals (e.g. every six months), there is a sticker on the upper edge of the combi filter on which you can enter, for example, the date it was inserted or changed.
Cleaning and maintenance
![]()
Before cleaning, always ensure that the mains plug of the air cleaner has been properly disconnected.
Cleaning the filter
Regular cleaning of the filter (once a month) is a prerequisite for hygienic and fault-free operation.
- Clean the three-layered filter using the brush attachment of a vacuum cleaner. To carry out a thorough clean, pull out the pre-filter and clean the activated carbon filter located behind it and the HEPA filter located at the rear, also using the brush attachment from a vacuum cleaner. Then replace the pre-filter on the HEPA filter.
Activated carbon filter | HEPA filter H 13 |
| |
Front | Rear |
![]()
The three-layered filter should be changed after 4320 operating hours (see "Filter change" section). The three-layered filter cannot be washed.
Cleaning the housing
Clean the housing of the air cleaner with a damp cloth (water or a mild cleaning solution). When cleaning, do not use any solvents or other aggressive or abrasive cleaning agents, as the surface may become damaged.
Storage
If you do not plan to use the device for a long period of time, we recommend that you clean it and store it in the original packaging in a dry environment, ensuring it is not weighed down by additional items.
Accessories and replacement parts
Replacement parts and wearing parts are available from the corresponding service address (according to the service address list). Please state the corresponding order number.
Designation | Item number and/or order number |
Pre-filter, combi filter (HEPA + activated carbon) | 693.01 |
What if there are problems
Problem | Cause | Solution |
The device will not switch on | The housing cover is not correctly installed. | Ensure that the housing cover is correctly installed. |
The three-layered filter is not correctly inserted. | Ensure that the three-layered filter is correctly inserted. |
The mains part plug is not plugged in. | Plug the mains part plug into a suitable socket. |
Insufficient passage of air | The filters are dirty | Clean the filters (see "Maintenance and storage" section). |
The air intake/air outlet is blocked. | Ensure that the air intake/air outlet is not blocked. |
The device is very loud | There is a foreign body in the air intake/air outlet. | Remove the foreign body from the air intake/air outlet. |
The filters are clogged. | Clean the filters (see "Maintenance and storage" section). |
The filters are not correctly inserted. | Insert the filters correctly. |
The air cleaner is positioned on an uneven surface. | Position the air cleaner on a level surface. |
Technical specifications
Model | LR 210 |
Mains voltage | See type plate on the device |
Output | 60 W |
Dimensions (L x W x H) | 275 x 175 x 308 mm |
Weight | 2.9 kg |
Suitable for rooms | 10 m² (ANSI/AHAM AC-1 2015) - 26 m² (NRCC 54013-2011) |
Volume | approx. 50 dB (Level 3) |
Permissible operating conditions | +5°C to +40°C, ≤ 90% relative humidity (non-condensing) |
Protection class | Protection class II / |
Air flow rate | 110 m3/h |
Warnings and safety notes
Read the notes carefully! Non-observance of the following information may result in personal injury or material damage.
![]()
Keep packaging material away from children to avoid danger of suffocation.
![]()
- This device may be used by children over the age of eight and by people with reduced physical, sensory or mental skills or a lack of experience or knowledge, provided that they are supervised or have been instructed on how to use the device safely, and are fully aware of the consequent risks of use.
- Children must not play with the device.
- Cleaning and user maintenance must not be performed by children unless supervised.
- Disconnect the device from the mains supply during cleaning.
- Clean the device using only the methods specified. Under no circumstances must liquid enter the fan unit.
- Do not use any solvent-based cleaning products.
- If the mains connection cable of this device is damaged, it must be disposed of. If it cannot be removed, the device must be disposed of.
![]()
Electric shock
As with every electrical device, use this air cleaner carefully and cautiously, in order to avoid hazards due to electric shock.
- Therefore, observe the following instructions for use:
- do not operate the device at voltages other than those indicated on the device (the type plate is located on the back of the device),
- never if it or its accessories show visible signs of damage
- not during a thunderstorm
- In the event of defects or operational faults, switch the device off immediately and disconnect it from the mains socket. Do not pull on the mains cable or on the device to disconnect the plug from the socket. Never hold or carry the device by the mains cable. Keep the cables away from hot surfaces.
- Always switch off the device before disconnecting it from the mains.
- Never disconnect the mains plug with wet or damp hands.
Keep the device away from sources of heat as the housing could melt and trigger a fire. - Ensure that the openings of the device and the mains cable do not come into contact with water, steam or other liquids.
- Do not use the device in close proximity to flammable or explosive gas mixtures.
- Never reach for a device that has been submerged in water. Disconnect it from the mains plug immediately.
- Do not use the device if it or its accessories are visibly damaged.
![]()
Repairs
- Only specialist personnel may perform repairs on electrical devices. Improper repairs may subject users to considerable danger. For repairs, please contact Customer Services or an authorised retailer.
- Do not open the fan unit.
![burn hazard]()
![]()
![burn hazard]()
Risk of fire
There is a risk of fire if the device is used improperly or these instructions for use are ignored.
Therefore, observe the following instructions for using the air cleaner:
- Never use underneath a cover, such as a blanket, pillow etc.
- Never use near petrol or other highly flammable substances.
![]()
Handling
The device must be switched off and disconnected from the mains after every use and before cleaning.
- Do not place any objects in device openings or in rotating parts. Ensure that the moving parts can move freely at all times.
- Do not place any objects on the device.
- Do not expose the device to high temperatures.
- Protect the device against sunlight and impacts and do not drop it.
- Never shake the device.
- Place the device on a firm and level surface.
Warranty / Service
Beurer GmbH, Söflinger Straße 218, 89077 Ulm, Germany (hereinafter referred to as "Beurer") provides a warranty for this product.
Documents / ResourcesDownload manual
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.
Download Beurer LR 210 - Air Purifier Manual
Need help?
Do you have a question about the LR 210 and is the answer not in the manual?
Questions and answers