Electrical Symbols; Technical Specifications - UNI-T UT225B Operating Manual

High voltage transformer turns ratio tester
Table of Contents

Advertisement

The monitor software can indicate maximum, minimum and average values, and have multiple
functions including dynamic display, real-time monitoring, alarming threshold setting, alarming
indication, data viewing/saving/printing, etc.
UT225B has the same functions as High/Low Clamp Meter, Aerial Current Tester, and other
products.
III. Electrical Symbols
Extremely dangerous! The operator must follow the safety information strictly,
otherwise it may present a risk of electric shock, which can cause personal
injury or death.
Danger! The operator must follow the safety information strictly, otherwise it
may present a risk of electric shock, which can cause personal injury or death.
Warning! The operator must follow the safety information strictly, otherwise it
can cause personal injury or product damage.
Alternating Current (AC)
Direct Current (DC)
IV. Technical Specifications
1. Basic conditions:
Influence quantity
Ambient temperature
Ambient humidity
Distortion rate of sinusoidal wave
Signal frequency
External electric and magnetic
fields
Location of measured conductor
2. Technical parameters:
Functions
Power supply
Testing mode
Testing accuracy of
primary current
Testing accuracy of
secondary current
Measurement range of
turns ratio
Resolution of turns ratio
Dimensions of primary
clamp sensor
Dimensions of secondary
transformer
Basic conditions
23°C±5°C
40%~60%
1%
50Hz±5Hz
Shall be avoided
Place the measured conductor at the center of the
clamp jaws.
Testing on current and turns ratio of high/low-voltage current
transformer
and
identification of polarity and phase type.
DC6V LR03 alkaline dry batteries (1.5V AAA × 4), with the ability
to work for 30 hours continuously.
By clamp sensor (CT)
Range: 0.0A~800A
Resolution: 0.1A
Accuracy: ±0.5%FS
Range: 0.00mA~5A
Resolution: 0.01mA
Accuracy: ±0.5%FS
1~500
0.1
Clamp jaws size:
External dimensions: 76mm × 255mm × 31mm
Clamp jaws size:
External dimensions: 137mm × 40mm × 19.5mm
2
Work conditions
-15°C±50°C
70%
3%
45Hz±65Hz
transformer
primary/secondary
48mm
8mm
Remark