Operation
Turning
the fan on
[] Pull the deflector out.
The hood will operate at power level "2".
The On/Off indicator and the second
"-/+" indicator will lighL
Semecting the power
_eve_
Depending on how much the air needs
to be filtered, there are four power
levels available.
[] Use the "_/+" buttons to select the
power level required.
The indicators show which power level
has been chosen.
For normal cooking a low to medium
level is usually sufficient.
For frying or cooking food with a strong
aroma use the highest level.
Fan performance
The maximum air flow capacity is
625 cfm. Factors such as narrow duct
diameter and bends will affect this
value.
Level 1 operates at 40% capacity
Level 2 operates at 60% capacity
Level 3 operates at 80% capacity
Level 4 operates at 100% capacity
There will also be a slight decrease in
airflow for hoods operated in
recirculation mode due to the active
charcoal filter.
Turning
the fan off
[] Push the deflector back in.
The next time the deflector is pulled
out, the hood will operate on power
level "2".
or
[] Press the On/Off button to turn the
fan off.
The indicators go out.