1. INTRODUCTION
This instruction sheet provides the installation
procedure for the Digital Subscriber Line (DSL)/
Security Module Assembly 1479703-1 used in
AMP NETCONNECT HOME NET-WORKS media
convergence centers (MCC).
The structured cabling system is recommended to be
installed in accordance with Telecommunications
Industry Association and Electronic Industries Alliance
(TIA/EIA)-570, "Residential Telecommunications
Cabling Standard". Refer to that publication for
technical specifications on wiring and cables.
The module assembly can be mounted into a
front-loadable 18-port panel or other panels with
openings of the same dimensions. See Figure 1.
Dimensions in this instruction sheet are in metric
NOTE
units [with U.S. customary units in brackets].
Figures are not drawn to scale.
i
Reasons for reissue of this instruction sheet are given
in Section 5, REVISION SUMMARY.
AMP NETCONNECT logo is a trademark of TE Connectivity.
©2012 Tyco Electronics Corporation, a TE Connectivity Ltd. company
All Rights Reserved
*Trademark
TE Connectivity, TE connectivity (logo), and TE (logo) are trademarks. Other logos, product and/or Company names may be trademarks of their respective owners.
AMP NETCONNECT* HOME NET-WORKS*
Residential Cabling System (RCS)
DSL/Security Module Assembly 1479703-1
Figure 1
To obtain information on AMP NETCONNECT*
products, call PRODUCT INFORMATION at the
number at the bottom of this page, or visit the
AMP NETCONNECT website at
www.ampnetconnect.com.
2. DESCRIPTION
Components and features of the module assembly are
shown in Figure 1. The module assembly is supplied
with the module assembled into the plastic interface
housing. The RJ31 shorting plug and RJ14 Telco
jumper cord is supplied loose.
3. INSTALLATION PROCEDURE
TOOLING ASSISTANCE CENTER 1-800-722-1111
PRODUCT INFORMATION 1-800-522-6752
Front-Loadable 18-Port Panel
(Unloaded, Ref)
Latch (Each Side of Interface Housing)
Press Inward to Disengage from Panel
RJ14 Telco Jumper
(2-Pair, 127 mm [5.0 in.]
1. Install the interface housing into the panel as
shown in Figure 1. To remove, press the latches
inward until they disengage from the panel.
2. Connect the telephone service cable to the
module port marked INPUT.
3. If no security panel is connected to the module
port marked RJ31X, insert the red RJ31 shorting
plug into the port marked RJ31X.
This controlled document is subject to change.
For latest revision and Regional Customer Service,
visit our website at www.te.com
Instruction Sheet
408-8987
06 MAR 12 Rev A
1 of 2

Advertisement

loading
Need help?

Need help?

Do you have a question about the AMP NETCONNECT HOME NET-WORKS 1479703-1 and is the answer not in the manual?

Questions and answers

Summary of Contents for TE Connectivity AMP NETCONNECT HOME NET-WORKS 1479703-1

  • Page 1 All Rights Reserved PRODUCT INFORMATION 1-800-522-6752 For latest revision and Regional Customer Service, *Trademark visit our website at www.te.com TE Connectivity, TE connectivity (logo), and TE (logo) are trademarks. Other logos, product and/or Company names may be trademarks of their respective owners.
  • Page 2 408-8987 Either the RJ31 shorting plug or the security panel The module port marked BYPASS LINE OUTPUT NOTE NOTE must be installed to provide Line 1 service to the is available in the event of a DSL modem or port marked OUTPUT. See Figure 2. security panel failure.