Pioneer LD-1100 Service Manual page 13

Laser disc player
Hide thumbs Also See for LD-1100:

Advertisement

LD-1100
Test
dj.
Step
Mode
Scope
Servo
Point
Adj
Adj
nd
Detai
No.
Range
Loop
Point
justment and Check
Details
К
|
Make sure the followings
|
Etp>0.65Eto, and Etn>0.65Eto
If not, the slider needs realignment.
Insert a low-pass filter (47-kilohms/0.01uF)
|
between the probe (10:1) and scope input (CH-Y),
|
set the oscilloscope into X-Y mode.
Connect the probe to TP-7, and verify the ground
level in CH-Y input. CH-X is not used. While
scanning to forward direction, adjust VR7 to ob-
tain a positive voltage depending on the mirror
rank. Mirror ranks and set points are shown below.
Disconnect the low-pass filter, and reset the oscil-
loscope to normal
mode.
:
d
| MIRROR
RANK
SET
POINT
(V)
|
[CODE
COLOR
|
C1
BLK
+0.50+0.05
С2
RED
+0.55+0.05
i
C3
YEW
+0.60+0.05
D
BLU
+0.70+0.10
GRN
10901010
|
13