PureStorage FlashArray Troubleshooting Manual

Storage replication adapter (sra)

Advertisement

Quick Links

KNOWLEDGE - OFFLINE PDF COPY
Troubleshooting
FlashArray Storage
Replication Adapter (SRA)
Generated On Thu, 29 Feb 2024 22:59:31 GMT
Confidential - Under NDA
For the latest information, please visit
http://support.purestorage.com/Solutions/VMware_Platform_Guide/Troubleshooting_for_VMware_Solutions/
Site_Recovery_Manager_Troubleshooting/Troubleshooting_FlashArray_Storage_Replication_Adapter_SRA
© 2015-2024 Pure Storage® ("Pure"), Portworx® and associated its trademarks can be found
here
as and its virtual patent marking
program can be found here. Third party names may be trademarks of their respective owners. The Pure Storage products and
programs described in this documentation are distributed under a license agreement restricting the use, copying, distribution,
and decompilation/reverse engineering of the products. No part of this documentation may be reproduced in any form by any means
without prior written authorization from Pure Storage, Inc. and its licensors, if any. Pure Storage may make improvements and/or
changes in the Pure Storage products and/or the programs described in this documentation at any time without notice. This
documentation is provided "as is" and all express or implied conditions, representations and warranties, including any implied
warranty of merchantability, fitness for a particular purpose, or non-infringement, are disclaimed, except to the extent that
such disclaimers are held to be legally invalid. Pure shall not be liable for incidental or consequential damages in connection
with the furnishing, performance, or use of this documentation. The information contained in this documentation is subject to
change without notice.
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FlashArray and is the answer not in the manual?

Questions and answers

Summary of Contents for PureStorage FlashArray

  • Page 1 KNOWLEDGE - OFFLINE PDF COPY Troubleshooting FlashArray Storage Replication Adapter (SRA) Generated On Thu, 29 Feb 2024 22:59:31 GMT Confidential - Under NDA For the latest information, please visit http://support.purestorage.com/Solutions/VMware_Platform_Guide/Troubleshooting_for_VMware_Solutions/ Site_Recovery_Manager_Troubleshooting/Troubleshooting_FlashArray_Storage_Replication_Adapter_SRA © 2015-2024 Pure Storage® (“Pure”), Portworx® and associated its trademarks can be found...
  • Page 2 This article provides a guide to troubleshooting the Pure Storage FlashArray SRA. Locating logs - Linux appliance The SRA's logs are located in: /var/log/vmware/srm/SRAs/sha256{characterSpamHere} This directory should have the logs referenced below. The SRM's logs are located in: /var/log/vmware/srm/ Locating logs - Windows appliance...
  • Page 3 Registry. It is usually vCenter Site Recovery Manager\InstallPath C:\Program Files\ VMware\VMware vCenter Site Recovery Manager\bin 3. In the SRM folder, navigate to the "storage/sra/purestorage" folder. 4. Confirm that the following files are present (filename case may vary): command.pl PureSRA.exe PureSRA.pdb...
  • Page 4 Errors andWarnings, respectively. They are usually indicative of what went wrong. For example, the entries below indicate that the SRA could not connect to an array: [02/11/2015 09:40:56,SRMCommandHandlerBase.cs:ConnectToInputAr<wbr/>rays,W] Connection failed to FlashArray at 10.66.50.90 using connection localArray [02/11/2015 09:40:56,SRMCommandHandlerBase.cs:ConnectToInputAr<wbr/>rays,E] "PureRestException: HttpStatusCode = 'BadRequest', RestErrorCode = 'InvalidVersion', Details = '', InnerException = ''"...
  • Page 5 Additionally, the SRA logs the HTTP requests (URL only) and their response codes. Look for "Rest Library transcript:" in the log. In the HTTP transcript that follows, look for "PureStorage.Rest Error:". Note that many HTTP errors are benign and expected (e.g. we test for the existence of a volume by asking the array about it; if the array responds with a does-not-exist error, we know it doesn't exist), so view errors in the HTTP transcript in the context of other clues in the log.
  • Page 6 • Launch the Registry Editor. • Create the registry key (or navigate to it if it HKEY_LOCAL_MACHINE\SOFTWARE\PureStorage\SRA already exists). • Create a DWORD Value named "HTTPTimeoutInSeconds", if it doesn't exist already. • Change the value to the desired HTTP timeout value (e.g. 120 seconds, in decimal), and press OK.