  • Page 1 User Manual Model ID: REM3IP Model ID: REM3IPSQ...
  • Page 2 Edition Notes The REM 3IP and REM 3IPSQ User Manual includes a description, safety precautions, installation, programming, operation and maintenance instructions for the REM 3IP and REM 3IPSQ as of the release date of this edition. Trademarks Chauvet, the Chauvet logo, and REM are registered trademarks or trademarks of Chauvet & Sons, LLC (d/ b/a Chauvet and Chauvet Lighting) in the United States and other countries.
  • Page 3: Table Of Contents

    Mounting with Steel Struts ............... Spacers....................Safety Cable Installation ................5. Joining Each REM 3IP and REM 3IPSQ........Vertically Joining the Panels..............Vertical Panel Connection ............... Horizontally Joining the Panels ............REM 3IP and REM 3IPSQ User Manual Rev. 1...
  • Page 4 Table of Contents Horizontal Panel Connection ..............6. Connecting & Cabling Each REM 3IP and REM 3IPSQ... Testing Signal and Power Connections..........Using the REM 3IP and REM 3IPSQ Test Button ....... Connecting Power and Signal Cables ..........Connecting the Signal Between Joined Panels ........
  • Page 5: Before You Begin

    Important installation or configuration information. The product may not function correctly if this information is not used. Useful information. Pinch point warning. REM 3IP and REM 3IPSQ User Manual Rev. 1...
  • Page 6: Safety Notes

    • In the event of a serious operating problem, stop using immediately. If this Chauvet product requires service, contact Chauvet Technical Support. REM 3IP and REM 3IPSQ User Manual Rev. 1...
  • Page 7: Fcc Statement Of Compliance

    LEDs, contributing to shorter lifespans if always used at full intensity. The average LED lifespan is 40,000 to 50,000 hours. To extend LED lifespan, maintain proper ventilation around the product, and limit the overall intensity. REM 3IP and REM 3IPSQ User Manual Rev. 1...
  • Page 8: Introduction

    2. Introduction Product Description REM 3IP and REM 3IPSQ are bright 4500 NITS indoor/outdoor hybrid video wall solutions with a 3.9mm pitch, integrated convex/concave curving capabilities, and universal magnetic LED modules. Their DCI-P3 color gamut LEDs offer 26% more color possibilities compared to standard sRGB/Rec.709 LEDs. With...
  • Page 9: Product Overview

    Seetronic etherkon Seetronic etherkon signal through port signal through port Latch Latch M10 threaded mounting hole M10 threaded Corner protector Alignment bolts (x4) mounting hole Alignment conicals Receivers Alignment magnets Alignment holes REM 3IP and REM 3IPSQ User Manual Rev. 1...
  • Page 10: Pixels Per Panel

    REM 3IP REM 3IPSQ Each pixel is 1 tri-color LED. The following table provides the pixels per panel in each REM 3IP and REM 3IPSQ. For detailed specifications, refer to the Technical Specifications table at the end of this User Manual.
  • Page 11: Rem 3Ip And Rem 3Ipsq Led Module Removal

    REM 3IP and REM 3IPSQ LED Module Removal Removing a Module from the Rear To remove an LED module from the rear of the REM 3IP and REM 3IPSQ: 1. Identify which module needs to be removed. 2. Carefully grip the module by the handles from the rear of the panel assembly.
  • Page 12: Removing And Replacing The Led Masks

    8 Masks per Module To replace an LED mask on an REM 3IP and REM 3IPSQ LED module, follow the instructions below: 1. Remove the module from the REM 3IP and REM 3IPSQ (see REM 3IP and REM 3IPSQ LED Module Removal).
  • Page 13: Product Dimensions

    0.5 in 12 mm 1.4 in 36 mm 9.8 in 250 mm 39.4 in 1000 mm 4.5 in 115 mm 19.7 in 500 mm 4.7 in 120 mm 2.7 in 70 mm REM 3IP and REM 3IPSQ User Manual Rev. 1...
  • Page 14: Setup

    3. Setup AC Power The REM 3IP and REM 3IPSQ have an auto-ranging power supply and can work with an input voltage range of 100 to 240 VAC, 50/60 Hz. To determine the product’s power requirements (circuit breaker, power outlet, and wiring), use the current value listed on the label affixed to the product’s back panel, or refer to the product’s specifications chart.
  • Page 15: Mounting

    The REM 3IP and REM 3IPSQ can be assembled to provide any number of modular designs. The panels on the top can be securely hung from a truss or other stable surface. Always hang in a safe position with adequate space for ventilation, configuration, and maintenance.
  • Page 16: Rem-Rb 50Cm Ip Curve Dual Function Rig Bar Dimensions

    499.6 mm 4.72 in 120 mm 2.36 in 60 mm REM-RB 100CM IP Dual Function Rig Bar Dimensions Sold Separately 39.35 in 999.6 mm 4.72 in 120 mm 2.36 in 60 mm REM 3IP and REM 3IPSQ User Manual Rev. 1...
  • Page 17: Mounting/Hanging With Dual Function Rig Bar

    2. Insert alignment conicals into the alignment holes and allow magnets to connect. 3. Insert the rig bar latch locking bars into the receiver connections on the REM 3IP and REM 3IPSQ. 4. Twist the spring knob on the rig bar latch until it locks into place.
  • Page 18: Curving The Panels

    Mounting Curving the Panels The curve receiver of the REM 3IP and REM 3IPSQ and REM -RB50 CM IP Curve allows a convex or concave angle between rig bars and video panels without additional accessories. To set the angle to -5° (convex), -2.5° (convex), 0° (straight), +5° (concave), or +10° (concave): 1.
  • Page 19: Truss Installation

    All Rig Bars in a panel assembly must be mounted individually to the mounting point! Adjacent Rig Bars will NOT support the attached weight! WARNING: This product should only be used by competent and qualified persons. REM 3IP and REM 3IPSQ User Manual Rev. 1...
  • Page 20: Mounting/Stacking With Dual Function Rig Bar

    Do not release panel until the hanging hardware has been fully secured. Removing the Feet To remove the feet (alignment bolts) from the REM 3IP and REM 3IPSQ, twist them counter-clockwise with a 16 mm wrench until they come loose.
  • Page 21: Flat Wall Installation

    Spacers greater than 6.5 mm thick must be used at each mounting point, between the panels and the struts. The illustrations above are examples only. Please refer to all applicable local codes and regulations for the proper installation of the product. REM 3IP and REM 3IPSQ User Manual Rev. 1...
  • Page 22: Spacers

    When mounting to a flat wall, spacers greater than 6.5 mm thick must be used at each mounting point, between the panels and the struts, as in the diagram below. Steel Strut Strut nut washer (spacer) Washer (x2) Washer LED Module M8 Bolt Strut nut REM 3IP and REM 3IPSQ User Manual Rev. 1...
  • Page 23: Safety Cable Installation

    Mounting Safety Cable Installation Safety cables may be attached to the REM 3IP and REM 3IPSQ. To attach safety cables to the REM 3IP and REM 3IPSQ, follow the instructions below: 1. Attach the clip at one end of the safety cable to the handle of the module.
  • Page 24: Joining Each Rem 3Ip And Rem 3Ipsq

    Vertically Joining the Panels Each REM 3IP and REM 3IPSQ can be easily joined vertically to a truss using an optional rig bar and the 2 receiver connections located at the top corners of each panel. Use the connections at the bottom of each panel to connect additional panels.
  • Page 25: Vertical Panel Connection

    This is normal. Warning! The magnetic attachments are not load-bearing, and are intended for alignment assistance only. Do not release panel until the hanging hardware has been fully secured. REM 3IP and REM 3IPSQ User Manual Rev. 1...
  • Page 26: Horizontally Joining The Panels

    Joining Each REM 3IP and REM 3IPSQ Horizontally Joining the Panels Each REM 3IP and REM 3IPSQ can be easily joined horizontally using the latch connections on the inside, upper and lower left sides of each panel. Horizontal Panel Connection Use the following instructions to join panels horizontally: 1.
  • Page 27: Connecting & Cabling Each Rem 3Ip And Rem 3Ipsq

    Using the REM 3IP and REM 3IPSQ Test Button Each REM 3IP and REM 3IPSQ has a test button, used to ensure all LEDs are functional. Use the Test button on each panel to perform a self-test. If self-testing, the user must perform the test individually for each REM 3IP and REM 3IPSQ.
  • Page 28: Connecting Power And Signal Cables

    The screen resolution desired for the video wall display. The Novastar MX40 Pro is required to operate an REM 3IP and REM 3IPSQ video wall system. Diagrams of how the REM 3IP and REM 3IPSQ panels and the Novastar MX40 Pro connect follow later in this manual.
  • Page 29: Signal Chain Rectangles

    Nova, they form horizontal rows and vertical columns in rectangular arrangements. Each port of one of the above mentioned VIP Drive products can connect to 20 REM 3IP and REM 3IPSQ panels. If more than 20 panels are used, more than 1 output port from the VIP Drive will be required.
  • Page 30: Connecting The Power Between Joined Panels

    Refer to the following diagrams for an example of power connection from the main and to each connected panel. This example is using the REM 3IP and REM 3IPSQ power linking 5 panels horizontally @ 120 V. Power Linking Cable...
  • Page 31: Led Module Care And Replacement

    7. LED Module Care and Replacement REM 3IP and REM 3IPSQ Modules Each REM 3IP and REM 3IPSQ has 2 or 4 LED modules connected to the panel frame by magnets. Each module has connectors that connect to the main processing unit.
  • Page 32: Rem 3Ip And Rem 3Ipsq Serviceability

    The REM 3IP and REM 3IPSQ control module can be accessed and serviced from either the front of the panel or the rear of the panel at any time, so panels can be serviced when access to either the front or the rear is restricted or impossible.
  • Page 33: Typical Rem 3Ip And Rem 3Ipsq Hanging Installation

    Step 2 Apply power and run the self-test for each REM 3IP and REM 3IPSQ to ensure all LEDs and inside connections in each panel are working (optional). Step 3 Create a stable mounting surface (e.g., truss or other stable surface) for REM 3IP and REM 3IPSQ...
  • Page 34: Operation

    Total panel orientation (when compatible) The NCP file does not contain brightness/chroma calibration data or mapping data (panel layout). Each of these are stored as separate files.To load a new NCP file onto an REM 3IP and REM 3IPSQ panel, follow the steps under...
  • Page 35: Operating Nova Vmp

    1. Launch Nova VMP software and locate the Device list menu. 2. Under the Device list menu, select the desired processor (i.e. Novastar MX40 Pro). 3. Once the desired device is selected, the canvas will populate. REM 3IP and REM 3IPSQ User Manual Rev. 1...
  • Page 36: Selecting A Signal Source

    Selecting a Signal Source To select a source: 1. Ensure that the Source tab is selected. Locate the source list at the bottom of the screen. 2. Select the desired signal. REM 3IP and REM 3IPSQ User Manual Rev. 1...
  • Page 37: Customizing The Canvas

    1. Locate the three custom mapping buttons above the canvas. 2. Each button will customize the canvas differently. Select the Cabinet only button and all panels will be visible on the canvas. REM 3IP and REM 3IPSQ User Manual Rev. 1...
  • Page 38 Operation 3. Select the Source Only button and the source will be visible on the canvas. 4. Select Both to show the source and cabinet option on the canvas. REM 3IP and REM 3IPSQ User Manual Rev. 1...
  • Page 39: Mapping Video Panels

    The top value denotes the number of panels mapped against the number detected (i.e 0/2), and the bottom value denotes the total capacity that has been mapped (i.e 0%). 3. Drag desired panel onto the canvas. REM 3IP and REM 3IPSQ User Manual Rev. 1...
  • Page 40 Operation 4. Press and hold to select the desired panel on the canvas. Drag the panel to map it on the canvas. Follow the previous steps to map the entire canvas. REM 3IP and REM 3IPSQ User Manual Rev. 1...
  • Page 41: Changing The Video Panel Orientation

    Operation Changing the Video Panel Orientation It is possible to move the REM 3IP and REM 3IPSQ panels without manually dragging them within the canvas. To change the video panel orientation: 1. Ensure the Layout tab is selected. Select the panel on the canvas to be moved.
  • Page 42: Rotating The Video Panel Orientation

    Operation Rotating the Video Panel Orientation When mounting REM 3IP and REM 3IPSQ panels sideways (90° or 270°), their orientation must be set in the mapping software. To do this through Nova VMP: 1. Ensure the Layout tab is selected. Select the panel on the canvas to be moved.
  • Page 43: Updating Cabinet Firmware

    Operation Updating Cabinet Firmware To update the firmware of REM 3IP and REM 3IPSQ products through VMP. 1. Select the Tools menu from the menu bar. 2. Select maintain from the tools menu. 3. Under the new display, select the cabinet tab to provide access to the firmware installation.
  • Page 44: Updating Controller Firmware

    1. Follow steps 1-2 from the previous section. 2. Under the new display, select the controller tab to provide access to the firmware installation. 3. Select the desired update location by selecting the corresponding box(es). REM 3IP and REM 3IPSQ User Manual Rev. 1...
  • Page 45: Technical Information

    As a rule, clean this product at least twice a month. Dust build-up reduces light output performance and can cause overheating. This can lead to reduced light source life and increased mechanical wear. To clean a REM 3IP and REM 3IPSQ, follow the recommendations below: 1. Unplug the panel from power.
  • Page 46: Technical Specifications

    Max. Tall/Novastar MX40 Max. Tall/Novastar MX40 4 @ 1080 5 @ 1344 6 @ 1680 8 @ 2160 Ordering Product Name Item Name Item Code UPC Number REM3IP REM3IP X4 23092118 781462224660 REM 3IP and REM 3IPSQ User Manual Rev. 1...
  • Page 47 8 @ 1080 10 @ 1344 13 @ 1680 16 @ 2160 Ordering Product Name Item Name Item Code UPC Number REM 3IPSQ REM3IPSQX8 23092120 781462224684 UL 62368-1 CSA C22.2 No. 62368-1 E114016 REM 3IP and REM 3IPSQ User Manual Rev. 1...
  • Page 48: Contact Us

    For warranty terms and conditions and return information, please visit our website. For customers in the United States and Mexico: www.chauvetlighting.com/warranty-registration. For customers in the United Kingdom, Republic of Ireland, Belgium, the Netherlands, Luxembourg, France, and Germany: www.chauvetlighting.eu/warranty-registration. REM 3IP and REM 3IPSQ User Manual Rev. 1...

This manual is also suitable for:

Rem 3ipsq

Table of Contents