- - - - - - S P E C I F I C A T I O N S - - - - - - -
1. MECHANICAL DESCRIPTION
Dimension:
Height:
Width:
Depth:
Weight:
Picture Tube:
Tilt:
4.4" {112mm) max.
6.0" {152mm) max.
7.4" {188mm) max.
3.75 lbs (1.7kg) max.
150BGB31
Size
5"
Def. Angle 70°
Neck dia
0.79" {20mm)
Phosphor
P31
00
2. ENVIRONMENTAL
Temperature:
Operating:
0 - 55°C
Non-operating:
-40 - 65°C
Storage and shipment:
-40- 65°C
Humidity:
Operating, Non-operating, Storage and Shipment:
5- 90% {No condensation)
Altitude:
Operating:
0 - 12,000 feet (0 - 3,600m)
Non-operating:
0 - 12,000 feet (0 - 3,600m)
Storage and shipment:
0 - 40,000 feet (0 -12,000m)
Vibration and shock (Packaged condition):
Vibration:
Frequency:
Vertical:
Horizontal:
Shock:
5- 50 Hz
1.25G
0.75G
Bottom:
Height
21.65" {55cm)
Front, Back, Side,
Corner and Edge:
Height
9.84" {25cm)
3.
ELECTRIC PERF.ORMANCE
Power Supply:
Input Voltage:
12V DC
Input Current:
0.8A max.
Input Signals:
Video Signal:
Polarity:
Positive
Signal Level:
TTL
Input Imp.:
75 ohm min. 40pF max.
Vertical Sync:
Polarity:
Positive
Signal Level:
TTL
Input Imp.:
1 k ohm min. 40pF max.
-2-
Horizontal Sync:
Polarity:
Positive
Signal Level:
TTL
Input/mp.:
1kohm
Note:
Max rise and fall times {from 10% to 90%) of in-
put signals are less than 10ns.
Image test condition:
Display:
Full flat field (40 ft-L)
Brightness:
Max.
View Direction:
Parallel to the CRT axis
Ambient Temperature:
Room temperature
Supply Voltage:
12V DC
Terrestrial Magnetism:
Horizontal field
Vertical field
0 Gauss
0.5 Gauss
Note:
1. All measurements shall be made under normal
conditions after an initial warm-up time of
more than 20 minutes.
2. Normal conditions are as stated in above image
test condition.
{Condition of following each
item is normal condition unless otherwise
stated.)
Image:
Image Size:
Distortion:
Centering:
H. Tilt:
Horizontal 4.17
±
0.18" (106
±
4mm)
Vertical
2.95 ± 0.18" { 75 ± 4mm)
See Fig. 1
See Fig. 2
See Fig. 3
Image size variation:
Cause
By Brightness
By Power Supply
Voltage
By Temperature
Resolution:
Image size variation from
Range of
the normal image size
variation
within 0.1" (2.5mm)
0 - 60 FL
(Horizontal and Vertical)
within± 0.14" (± 3.5mm)
12V DC± 3%
(Horizontal and Vertical)
within± 0.14" (± 3.5mm)
(Horizontal and Vertical)
25~~g
°C
500 TV line type {center)
350 TV line type {center)