Temtop LKC-1000 Series User Manual

Air quality monitor

Advertisement

LKC-1000 Series
Air Quality Monitor
User Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LKC-1000 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Temtop LKC-1000 Series

  • Page 1 LKC-1000 Series Air Quality Monitor User Manual...
  • Page 2 Factory A ecting Air Quality PM2.5 refers to fine (Particulate Matter 2.5) particles with diameter of 2.5 micrometers or less. Due to its tiny size, PM2.5 can be absorbed into bloodstream and the lungs, so that long-term exposure to high concentration of PM2.5 environment may cause eye and nose irritation, cough, asthma, emphysema, lung disease, heart attacks, cancer and etc.
  • Page 3 PM , PM , SO , NO , CO etc. Temtop follows EPA Standards to calculate and focus only for AQI of PM2.5&10. Important! It is usual for the detector to show higher values when ★ first switched on or not used for an extended period.
  • Page 4 Overview ① Air Inlet/Outlet ② LCD Screen ③ Power Button ④ PM2.5/PM10/Particles Button ⑤ USB Port ⑥ AQI/TEMP/HUM/Up Button ⑦ HCHO/TVOC Button ⑧ Running/Hold/Setting/Down Button ⑨ Bracket Function Model LKC-1000S LKC-1000S+ LKC-1000S+ 2nd LKC-1000S 2nd Function √ √ √ √ PM2.5 √...
  • Page 5: Specifications

    Measuring range: 0-2mg/m Resolution: 0.01mg/m TVOC* Measuring range: 0-5mg/m Resolution: 0.01mg/m *For LKC-1000S+ /LKC-1000S+2nd Only Note: The above data are from Temtop Laboratory. Operation Warning! Indoor use: Keep the room/area airtight for 10 ★ minutes to obtain more accurate results.
  • Page 6 PM10 Concentration Particle Count (For Ref)* Air Quality Indicator PM2.5 Graph View �� s �� s �� s �� s * The particle counts are for reference only. For accurate particle counts please choose a professional particle counter from Temtop.
  • Page 7 PM10 ��� ��� PM10 Graph View �� s �� s �� s �� s Particles ��.� ��.� Particle Graph View ��.� �.� *���� �� s �� s �� s �� s 2.2 AQI Button Please click the button to view the following four interfaces. Press and hold button for 2 seconds to switch between °C or °F.
  • Page 8 ℉ TEMP �� �� TEMP Graph View �� �� �� s �� s �� s �� s ��� �� HUM Graph View �� �� �� s �� s �� s �� s 2.3 HCHO Button Please click the button to view the following three interfaces. 0.02 HCHO Concentration TVOC Concentration...
  • Page 9: Settings Menu

    TVOC mg/m �.��� �.��� TVOC Graph View �.��� (LKC-1000S+/1000S+ 2nd) �.��� �� s �� s �� s �� s Note: 1) Please click "II/ " button to switch between running mode and holding mode. In running mode, the detector always displays currently detected data. In holding mode, the detector paused the detection function and will stop updating data on the screen.
  • Page 10 3.1 Power Saving (Example Of Button Operation): Press the button to scroll up or down and press the button to confirm. Press the button to switch to the item you want to set. Press the button to increase or decrease the current value. Then press the button to switch to save or exit, and press button to save the setting or exit the interface.
  • Page 11 Note: 1. Please ensure that you can calibrate under fresh air outdoors. 2. During the calibration process, please do not perform other operations until the calibration is successful and you return to the previous level screen. 3.2.2 TEMP & HUM Calibration You can calibrate the temperature and humidity by modifying the "OFF"...
  • Page 12 3.3 Date and Time In this interface, you will see the figure below. Date and Time Press the AQI or ||/> button to set the current value, press the PM2.5 or HCHO button to switch to the next item. Save Exit 3.4 Storage Interval In this interface, you will see the figure below.
  • Page 13 ' HCHO ' button! After successful connection, the detector creates a removable storage device "TEMTOP" on the computer, which contains a folder named "HISTORY". This history folder contains a history file named after the time, e.g. "20230601". The history file is in CSV format and lists information such as date, PM2.5, PM10,...
  • Page 14: What's Included

    ≤0.5 >0.5 *Refers to EPA standards,with PM2.5 as the main responsible pollutant. What's Included LKC-1000 Series Detector x 1 USB Cable x 1 User Manual x 1 Q: Why data reading is unstable? A:If the airflow in the current sampling space is in an unstable...
  • Page 15: Warranty

    Sulphur dioxide( SO Ammoniak (NH Warranty Temtop warrants the included detector for 1 year from the date of original purchase. The item can be exchanged or returned within 30 days if the defect is not caused by artificial damage. Item...
  • Page 16 Tel: (+1) 408-898-2866 Sales: sales@temtopus.com Website: www.temtopus.com Elitech (UK) Limited Unit 13 Greenwich Business Park, 53 Norman Road,London, SE10 9QF Tel: (+44)208-858-1888 Support: service@elitech.uk.com Website: www.temtop.co.uk Elitech Brazil Ltda R.Dona Rosalina,90-Lgara, Canoas-RS 92410-695,Brazil Tel: (+55)51-3939-8634 V1.4 Sales: brasil@e-elitech.com Website: www.elitechbrasil.com.br...

This manual is also suitable for:

Lkc-1000s+ 2ndLkc-1000s+