Bosch Greensource CDi Series Installation, Operation And Maintenance Manual page 10

Table of Contents

Advertisement

10 | Horizontal Configurability
NOTICE: Air coil is in close proximity to the
blower. Air coil fins are easily damaged.
Great care must be taken during this step to
avoid coil damage. Shipping cardboard can
be used as protection during blower
removal and installation.
4.
Slide blower assembly away from mounting bracket.
(Figure #23)
Figure # 23
5.
Remove and retain (1) vertical bracket by removing
(2) screws. (Figure #24)
Figure # 24
8733942411 (2017/07)
6.
Remove and discard horizontal blower bracket by
removing (3) screws. (Figure #25)
7.
Rotate the blower into its new position.(Figure#26)
8.
Remove and retain remaining vertical blower
bracket by removing (2) screws. (Figure #27)
9.
Remove the blower assembly by sliding it forward.
(Figure #28)
Unit top is notched to allow blower to slide through.
Subject to change without prior notice
SM Series Heat Pump
Figure # 25
Figure # 26
Figure # 27
SM Series Heat Pump