Deflection Circuit Board; Process Circuit Board - Panasonic WV-3110 Service Manual

Color video camera
Hide thumbs Also See for WV-3110:
Table of Contents

Advertisement

7. CONTROL PANEL REMOVAL
Remove two screws
Remove one screw
CN103
Handle cover A
Remove one screw
Fig. 7-8
Fig. 7-11
Fig. 7-4
Remove two screws
Fig. 7-1
Remove one screw
Red --------
Remove two screws
Fig. 7-5
Fig. 7-12
Fig. 7-9
Remove four screws
Move the upper cover
Fig. 7-2
Fig. 7-6
Fig. 7-10
Remove one screw
Handle cover B
Fig. 7-7
Fig. 7-3
24
25
Remove the MIC holder by removing the two fixing
screws. (Fig. 7-2)
• Remove the E F mounting base by removing the one
fixingscrew. (Fig. 7-3)
Remove
one screw
Remove the four screws on the bottom cover and
remove the cover. (Fig. 7-6)
Remove the one screw on the handle cover B and
remove the handle cover B (Fig 7-7)
Note:
When reinstalling the indicating plate, place it
on
the standby power switch that its red por ­
tion is at the left side. (Fig. 7-5)
®
Remove the one screw by the E F connector and
move the upper cover as shown below.
So that the control panel fixing screws can be ob ­
served. (Fig. 7-9, 7-10)
Note:
• When installing the control panel to the control panel
base, set the indoor/outdoor switch and the white
balance switch on the control panel to the upper posi ­
tion for proper engagement.
• When installing the control panel with the control
panel base to the chassis, set the indoor/outdoor
switch to the upper (OUTDOOR) position and the
white balance switch to the lower (SET) position for
proper engagement.
Remove the two screws on the control panel and
remove the control panel from the chassis. (Fig. 7-11)
Remove the two control knobs, and the two screws
on the control panel base for removing the control
panel from the base. (Fig. 7-12)
Remove
four screws
IB
Remove the one screw on the handle cover A and
remove the handle cover A. (Fig. 7-8)
Remove the rear cover by removing the four fixing
screws. (Fig. 7-4)
• Disassemble
the
camera
and
the
viewfinder as
described
in
Section
2.
"DISASSEMBLY
PRO ­
CEDURE FOR ADJUSTMENT" on page 1.
• Disconnect the connector CN103 for the microphone
from the deflection circuit board, and remove the
microphone unit by removing the one fixing screw.
(Fig. 7-1)

Advertisement

Table of Contents
loading

Table of Contents