I/O Signal
Frequency
(FM)
Fault
alarm
signal
(ALo, AL),
AL»)
monitor
signal
Description
The
frequency
monitor
signal
(FM)
can
be
transmitted
by selecting
2 types
of signals
below.
©
Digital
monitor
for frequency
counter
This
monitor
outputs
the
same
frequency
pulse
train
as
the output
frequency.
The duty is
approx.
50%.
Approx. 10V
A EEL
ao
a
frequency
Frequency
comter
Monitor
for analog meter
This monitor
outputs
the duty
(t/T)
proportional
to the output
frequency.
Adjust
the variable
resistor
(M.ADJ)
and
the variable
resistor
of
frequency
counter
itself
so that
the meter
is
maximum
at the highest
frequency.
HER
D
Analog meter
H4
ee
k—+
t $ Varying
1l ms constant
CAUTION:
This
signal
is only for indicator.
It
cannot
be therefore
used
as a line
speed
signal.
This
signal
is transmitted
in abnormal
conditions.
fo
| In normal
conditions
fet
aac
a
S
Remarks
0O ~
10V
Full
scale
(Load
resistance:
10 ~
22
kR
1 mA max.)
Output
circuit
l
ALo
AL2
|
OO
ALI
1
Contact
specification
ac 250v, 2.5a 'gesigtance
0.2A
(cosġ=0.4)
(resistance
DC 30v, 3.04
'Jesi
0.7A (cos$20.4)
ONO
NES