Line Voltage And Fuse And Rear Panel
Each design of LINE VOLTAGE
and FUSE of
this model differs according to each destination
to be delivered.
How
to operate the SX-636
is quite the same
for
each
version.
However,
each
rear
panel
differs
according
to
LINE
VOLTAGE
and
FUSE design for each version.
Fig. A shows the LINE VOLTAGE
of a 120V
only model.
Fig. B shows the LINE VOLTAGE
of a 220V
only model.
Fig. C shows
a 5 line voltage (110V,
120V,
130V,
220V
and
240V)
model
whose
LINE
VOLTAGE
and FUSE
can be changed and set
as follows:
Changing Line Voltage Setting And Fuse
(Fig. D)
To remove
the fuse, turn the fuse cap located
on
the
line voltage selector
in the direction
indicated by the arrow.
Then remove the fuse
plug from the unit. Put the fuse plug back so
that the proper line voltage marking can be seen
through
the
cut
in the
edge
of the
plug.
Whenever
the
position
of
the
selector
is
changed, check the rating of the fuse. A 1.5A
fuse is to be used
for either 220V
or 240V
operation and a ЗА fuse rating for 110V, 120V
or 130V operation. If the rating of the fuse is
correct, replace cap.
Fuse Replacement
When
the fuse blows, remove the fuse cap and
replace the fuse with a new one.
зх-взв
Em
120V model
220V model
AC LINES
5 Line Voltage model
Line Voltage and Fuse
Fig. C

Advertisement

loading

This manual is also suitable for:

Sx-636 kcuSx-636 fvSx-636 gn