Power Outlet; Flooring - LG WT1801H A Series Owner's Manual

Hide thumbs Also See for WT1801H A Series:
Table of Contents

Advertisement

Available languages

Available languages

8
INSTALLATION
INSTRUCTIONS
INSTALLATION
INSTRUCTIONS
CHOOSE
THE PROPER
LOCATION
,ZLWARNING
-------_- -
• The washer
is heavy. Two or more
people are
required
when
moving and unpacking the wash-
er. Failure to follow
this warning
may result
in
damage
to property
or serious
bodily harm.
• Store
and
install the washer
where
it will not
be exposed
to temperatures
below
freezing
or
exposed
to outdoor
weather
conditions.
Failure
to follow
this warning
can cause serious
injury,
fire, electric
shock, or death.
• Properly
ground
the washer
to conform
with all
governing
codes and ordinances.
Failure to fol-
low this warning
can cause serious
injury, fire,
electric
shock, or death.
• To reduce
the risk of electric
shock, do not in-
stall the washer
in humid spaces.
Failure to fol-
low this warning
can cause serious
injury, fire,
electric
shock, or death.
• To ensure proper air flow, do not block the large
opening
on the bottom
of the washer
with car-
peting or other materials.
• Do not remove the ground
prong. Do not use an
adapter
or extension
cord.
Plug into a grounded
3-prong
outlet.
Failure
to follow
this warning
can cause serious
injury, fire, electric
shock,
or
death.
\
POWER
OUTLET
• The power
outlet
must
be within
60 in. (1.5 m) of
either side of the washer.
• The
appliance
and outlet
must
be positioned
so
that the plug is easily accessible.
• Do not overload
the outlet
with
more than one ap-
pliance.
• The outlet
must
be grounded
in accordance
with
current
electric
wiring
codes and regulations.
• A time-delay
fuse
or circuit
breaker
is recom-
mended.
NOTE:
It is the personal
responsibility
and obligation
of the product
owner
to have a proper outlet
installed
by a qualified
electrician.
FLOORING
• To minimize
noise and vibration,
the washer
MUST
be installed
on a solidly
constructed
floor.
• Allowable
slope under the entire washer
is a maxi-
mum
1 in. difference
from
side
to side or from
front to back.
• Installing
on carpeting
and soft tile surfaces
is not
recommended.
• Never install the washer on a platform
or weakly
sup-
ported structure.
NOTE: The washer
must be installed
on firm flooring
to minimize
vibration
during
the spin cycle. Concrete
flooring
is best,
but a wood
floor
is sufficient,
pro-
vided
it is built to FHA standards.
The washer
should
not be installed
on rugs or exposed
to weather.
40//s"
(102 cm)
1"
27"
/"
(25crn/_
-_
(686cm)
_
_(25cm)
To ensure
sufficient
clearance
for water
lines and
airflow,
allow
minimum
clearances
of at least
1 in.
(2.5 cm) at the sides
and 4 in. (10 cm) behind
the
unit.
Be sure
to allow
for wall, door,
or floor
mold-
ings that may increase
the required
clearances.
32"
55 _/s"
(140 cm)
(with
open
iid)
-_
(811
cm)
28 Sis"
-_
(721
cm)
26 s/4"
(68 cm)
3
1/2"
(9 cm)
Minimum
vertical
space
from
floor
to overhead
shelves,
cabinets,
ceilings,
etc.,
is 56 in.

Advertisement

Table of Contents
loading

Table of Contents