Maintenance:
Typical maintenance of the Solaris is recommended replacement of the UVC Lamp ev-
ery 18,000 hours approximately 2 years, for optimum results change lamps every year.
UV lamps undergo a photochemical process during operation. This slowly reduces the
amount of UV light generated to disinfect against airborne pathogens.
Note:
You must reset the service indicator light after each lamp replacement. With the
power on press and hold the RESET button for 10 seconds using a non-metallic
Implement. The LED should turn blue while the button is depressed. Release the RESET
button, and the LED should remain blue.
Important:
When installing new lamps, ensure that the lamp glass is free from any fingerprints or
debris, as this may alter the path of the UV energy. Use rubbing alcohol and a dry cloth
to remove any surface contaminants.
Replacement Lamp Log Sheet:
Included with the product is a replacement lamp log sheet. It is provided as a label so it
can be attached near the installation to ensure lamp replacements are being tracked.
Replacement Lamp Part Numbers:
10" Pure Spectrum Lamp for use in the PCO reactor chamber.........................AS-IH-1013-1
Warranty:
Ultravation® Solaris features Ultravation's lifetime warranty, with the exception of the
ultraviolet lamp(s), which are warranted for a period of one year after date of consumer
purchase.
This warranty does not include damage to the unit from accident, misuse or improper
installation.
If this product should become defective, Ultravation will elect to repair or replace the
product free of charge. Ultravation will return repaired or replaced warranted products
pre-paid to the customer, provided that the product was delivered pre-paid.
Ultravation shall have no responsibilities for charges incurred by the customer for
installation or removal of warranted items. Liability is limited only to the replacement or
repair of this product.
This warranty gives you specific legal rights, and you may also have other rights, which
vary from state to state. All returns must be accompanied by a return authorization
number, which may be obtained by contacting Ultravation, Inc.
Ultravation,
Inc.
67 Tubbs Ave. Brandon, VT 05733
Phone: 1-866-GO-UV-AIR (468-8247) • Fax: 802-287-9203
www.ultravation.com • info@ultravation.com
Copyright © 2008-2017 Ultravation Inc.
SLX-1024 OM2022
Ultravation
®
SOLARIS
Bring cleaner air to your life
Model # SLX1000/1024-2998
Whole House Air purifier with adjustable advanced
oxidation combined with 4x high output Plasma
generation.
Operating voltage: 24 VAC 40 VA.
Installation and Owners Manual
®
™
Need help?
Do you have a question about the SOLARIS SLX-1000 and is the answer not in the manual?
Questions and answers