the water tester or may lead to long testing
time.
If the ACW goes into a permanent Error
Mode during the test dive or water resistance
test, RESET THE UNIT: Remove the battery,
replace it and make a reset contact as follows
a) Place the movement module back to the
case.
b) Connect the reset
point to the case
(Fig. 5.3.34.).
c) Hold this contact
for more than 2
seconds (display
must be blank).
d) Open the contact
(Time
activates).
e) Make sure that
the time starts from 18:00 (6:00 PM)
Make sure that the
ACW is not in a
permanent Error Mode
after the test dive or
water resistance test.
Enter the Dive mode
and check the Surface
display. The ACW is
in the permanent Error
Mode if the ASC TIME symbol is displayed
(Fig. 5.3.35.) In that case you must RESET
THE ACW as instructed above.
Testing , electronic testers
(Witshi, Grainer, etc.)
1. Test the unit in low
pressure of 1 bar for
60 seconds (in air)
(Fig. 5.3.36). If the
unit passes the test,
take step 2.
2. Test the unit in high
pressure (min 6 bar,
max 9 bar) for 60
seconds (in air). If
the unit passes the
test, take step 3.
3. Keep the unit in water at 3 bar for 8 minutes
(Fig 5.3.37).
Version 2/2000, 14.8.2000
Mode
5
.
3
.
3
4
5
.
3
.
3
4
5
5
.
.
3
3
.
.
3
3
5
5
5
.
3
.
3
6
5
.
3
.
3
6
5
.
3
.
3
7
5
.
3
.
3
7
4. Make a water condensation test. Warm up the
unit e.g. on a warm plate to about 40°C
[104°F]. Drop cold water on the glass and
inspect the unit. If there is any evidence of
moisture inside the unit, there is a leak (Fig.
5.3.38 a and b).
5
.
3
.
3
8
5
.
3
.
3
8
18