5.3. SERVICE MEASURES

Do not attempt to open the ACW before reading
these instructions. Open the ACW only in a dry
and clean place at room temperature (18-25ºC
[65-78ºF]).
5.3.1. D
ISASSEMBLY OF THE UNIT
A. Disassembly of the unit:
1. Remove the strap or bracelet with the spring
bar tool (Fig. 5.3.1).
5.3.1
2. Loosen the bezel by turning it counter
clockwise with the bezel opening tool (Fig.
5.3.2. NOTE: The opening tool in the Figure is
not the current one in use).
5.3.2
3. Remove the mineral crystal with the suction
pad. Remove the O-ring. Do not reuse the old
O-ring, even if it seems to be in good
condition. Do not touch the display screen.
4. Remove the dial (Fig. 5.3.3).
5.3.3
Version 2/2000, 14.8.2000
5. Carefully remove the watch module by lifting
it out from the case with the module puller.
The puller hooks go into the holes of the
module. (Fig. 5.3.4) Do not damage the
internal parts of the module with the hooks.
Avoid damaging the flexprint that connects the
module to the pressure sensor and touching the
gold plated contacts.
5.3.4
6. Place the case carefully on a clean surface so
that the module back and battery side are
facing up (Fig. 5.3.5).
5.3.5