C. WV-BP134 (24V AC 60 Hz)
Connect the power cable to the AC 24V IN termi-
nal on the rear panel of the WV-BP 134.
AC 24V N
24V AC, 60 Hz
(19.5 V - 28 V)
Recommended wire gauge sizes for 24V AC line
Copper wire
#24
#22
#18
size (AWG)
(0.22mmv) | (0.33mm?) | (0. drame)
(0.83mmr)
of Cable
Caution:
To prevent fire or electric shock hazard,
use a UL listed wire (VW-1, style 1007)
should
be used
for DC
12V or AC
24V
Input Terminals.
Video Cable
1. It is recommended to use a monitor whose resolu-
tion is at least equal to that of the camera.
2. Set the termination switch to the 75Q position on
the last monitor.
A. Use a 75Q coaxial cable.
B. Set the termination switch to the 75Q position
on the last monitor and to the Hi-Z position on
the other monitors. Do not change the posi-
tions after setting.
C. The maximum extensible coaxial cable length
between the camera and the monitor is shown
below.