2. Parallel Interface Specifications
3. Handling and Installation Method
~ G B W ~
a
(Transm~ss~on
s~de
L -
-
- - - - - - - - - - - - - - - -
C=
recept~on s~de)
Note
1 :
@ Minimum 1.0 microseconds
@ M~nimum 1.0
microseconds,
maximum 500 mi-
--.'-
- - - - - - - - -
' ,
'
' 1 The applications vary depending on the prlnter used, so refer to the in-
struction manual of the printer used.
Printers that can be used
The SEC/P24-J84
supporting
printers can be used.
The printers for which Mitsubishi has confirmed operation are as follows.
Canon
BJC-6OOJ (color printer)
BJC-400J (color printer)
Epson
VP-600 (dot matrix kanji printer)
MJ-800C (color printer)
Cables that can be used
The printer cables that Mitsubishi has confirmed for use are as follows.
AC30PIO-20P
AC300PIO-20P
&,CAUTION
Use this module In the general specification environment prescr~bed
in the GOT User's Manual.
If this module is used outside of the general specification environ-
ment, electric shock, fire, malfunction or damage and degradation
to the product could result.
T u r n the power off when removing a unit. Trylng to remove the un~t
while the power is on could damage the unit or result In erroneous
operation.
When installing in the GOT module installation area, securely install
the module with module fixing screws.
If the module
IS
not correctly installed it could malfunction, have
problems, or fall off.
.Take precautions so that debris, such as sawdust or wiring debris,
does not get inside the module. If such debris does get inside it
could cause fire, trouble, or mahnction.
Do not disassemble or modify the module. Doing so could cause
trouble, malfunction, injury, or fire.
Do not touch the module's printed wiring board or electronic com-
ponents. Doing so could cause trouble In the module.
@The module 1 s made of plastlc so do not drop it or subject it to
strong impacts. Doing so could cause trouble.
Do not remove the module printed wlrlng boards from the case.
Doing so could cause trouble.
When discarding the product treat ~t as industnal waste.
(1)
Insert the model 70PRF printer
connector in the GOT top module
connection interface.
(2) Correctly install and tighten the
module fixing screws (2 screws).
Tighten the screws to a tighten-
ing toque in the range of 36 to 48
N-cm (3.7 to 4.9kg-cm). When re-
moving the module, remove it in
the reverse order of ~nstallation
after loosening the screws.