LD Didactic CASSY Instruction Manual

Power analyser
Hide thumbs Also See for CASSY:

Advertisement

Quick Links

Safety instructions
Please read first
This device has been designed for use in LD Didactic
experiments, and is therefore only intended for use in
dry rooms. If the device is used for other measure­
ments, the user is responsible for the risk assessment
and must take the necessary safety precautions.
All users should be instructed about the risk of electric
shock. The user of the measuring instrument must en­
sure compliance with the guidelines of the trade associ­
ation or other insurance carriers, country-specific re­
quirements, as well as regulations for schools and uni­
versities.
The Power Analyser CASSY meets the following stan­
dards:
Instruction sheet 727 100
Power Analyser CASSY (727 100)
Power Analyser CASSY Plus (727 110)
Measuring channels U and I
1
2
Mask
Display
3
4
Rotary selector and OK button
5
Cursor buttons
Start button
6
7
Display selection
USB-C connector
8
9
Power switch
LEDs and buzzer
10
Relay
11
12
Potential equalisation connection
Output channels (only Power Analyser CASSY
13
Plus)
Output, function generator output (only Power
14
Analyser CASSY Plus)
EC/EN61010-1-2001
Safety regulations for electrical equipment for mea­
surement, control, and laboratory use, Part 1: Gen­
eral requirements
Rated voltage range: 700 V AC and 1000 V DC
CAT III 300 (see table of permitted types of mains).
Pollution degree 2.
Use the analyser and accessories only as specified
in the operating instructions. Failure to follow these
instructions may affect the protective functions pro­
vided by the analyser.
Warning!
A "Warning" indicates circumstances and actions that
represent one or more sources of risk to the user.
Warning!
To avoid electric shock and fire hazard:
Read this entire manual carefully before using the
analyser and accessories.
Read all instructions thoroughly.
Do not work alone.
© by LD DIDACTIC GmbH · Leyboldstraße 1 · D-50354 Hürth · www.ld-didactic.com
Tel: +49-2233-604-0 · Fax: +49-2233-604-222 · Email: info@ld-didactic.de · Technical alterations reserved

Advertisement

Table of Contents
loading

Summary of Contents for LD Didactic CASSY

  • Page 1 The Power Analyser CASSY meets the following stan­ • Read all instructions thoroughly. dards: • Do not work alone. © by LD DIDACTIC GmbH · Leyboldstraße 1 · D-50354 Hürth · www.ld-didactic.com Tel: +49-2233-604-0 · Fax: +49-2233-604-222 · Email: info@ld-didactic.de · Technical alterations reserved...
  • Page 2 A and the selected channel, e.g. for chan­ nel B to A φ © by LD DIDACTIC GmbH · Leyboldstraße 1 · D-50354 Hürth · www.ld-didactic.com Tel: +49-2233-604-0 · Fax: +49-2233-604-222 · Email: info@ld-didactic.de · Technical alterations reserved...
  • Page 3: Technical Data

    P and for alternating values (RMS value), the load angle φ and the frequency f can also be measured. © by LD DIDACTIC GmbH · Leyboldstraße 1 · D-50354 Hürth · www.ld-didactic.com Tel: +49-2233-604-0 · Fax: +49-2233-604-222 · Email: info@ld-didactic.de · Technical alterations reserved...
  • Page 4: Scope Of Delivery

    The outputs can be activated via the menu bar. The following and RMS values functions are available: ◦ Tare (→ 0 ←) to zero the measured value © by LD DIDACTIC GmbH · Leyboldstraße 1 · D-50354 Hürth · www.ld-didactic.com Tel: +49-2233-604-0 · Fax: +49-2233-604-222 · Email: info@ld-didactic.de · Technical alterations reserved...
  • Page 5: Setting Measurement Parameters

    (see section 4.9). ment values should be deleted. © by LD DIDACTIC GmbH · Leyboldstraße 1 · D-50354 Hürth · www.ld-didactic.com Tel: +49-2233-604-0 · Fax: +49-2233-604-222 · Email: info@ld-didactic.de · Technical alterations reserved...
  • Page 6: Switching Off

    You can on­ accessed. ly zoom in on the x-axes as well by selecting a range. © by LD DIDACTIC GmbH · Leyboldstraße 1 · D-50354 Hürth · www.ld-didactic.com Tel: +49-2233-604-0 · Fax: +49-2233-604-222 · Email: info@ld-didactic.de · Technical alterations reserved...
  • Page 7: Mac Address

    "XXX" is replaced by the last three numbers of the seri­ al number. This name can be modified with Mobile Config (see IP address or the CASSY name in the address field of a Lab section 5.1)  and is used by Power Analyser CASSY e.g. as Doc.
  • Page 8 ±10 V  are provided. © by LD DIDACTIC GmbH · Leyboldstraße 1 · D-50354 Hürth · www.ld-didactic.com Tel: +49-2233-604-0 · Fax: +49-2233-604-222 · Email: info@ld-didactic.de · Technical alterations reserved...
  • Page 9: Function Generator

    In this way, e.g. specific ranges (see Tab. 2). switch-on processes can be observed. © by LD DIDACTIC GmbH · Leyboldstraße 1 · D-50354 Hürth · www.ld-didactic.com Tel: +49-2233-604-0 · Fax: +49-2233-604-222 · Email: info@ld-didactic.de · Technical alterations reserved...
  • Page 10 German and English language. The help texts provide addi­ MOBILE.CFG on Power Analyser CASSY. tional information on how to use Mobile Config. Download: https://www.leybold-shop.de/727100 © by LD DIDACTIC GmbH · Leyboldstraße 1 · D-50354 Hürth · www.ld-didactic.com Tel: +49-2233-604-0 · Fax: +49-2233-604-222 · Email: info@ld-didactic.de · Technical alterations reserved...
  • Page 11 Instruction sheet 727 100 11 / 15 Fig. 10: Mobile Config configures a Power Analyser CASSY by editing its hidden configuration file MOBILE.CFG. 4.2 Mobile Edit (contained in scope of delivery) 4.3 Mobile Control (contained in scope of delivery) Mobile Edit is a tool used by the instructor or author to add ex­...
  • Page 12: Current Measurement

    Show QR Code. The values. Fig. 13: In addition, the Power Analyser CASSY Web App displays the measurement data, tables, diagrams, and evaluations of a Power Analyser CASSY in up to four browsers. 4.5 VNC Viewer (free of charge) 4.6 CASSY App (free of charge)
  • Page 13: Voltage And Frequency Measurement

    The safety leads used must be rated for the expected voltage and current values. © by LD DIDACTIC GmbH · Leyboldstraße 1 · D-50354 Hürth · www.ld-didactic.com Tel: +49-2233-604-0 · Fax: +49-2233-604-222 · Email: info@ld-didactic.de · Technical alterations reserved...
  • Page 14 The safety leads values. used must be rated for the expected voltage and current values. © by LD DIDACTIC GmbH · Leyboldstraße 1 · D-50354 Hürth · www.ld-didactic.com Tel: +49-2233-604-0 · Fax: +49-2233-604-222 · Email: info@ld-didactic.de · Technical alterations reserved...
  • Page 15: Recycling And Disposal

    The connections of current paths should never be inter­ rupted unless the system or the experiment is switched © by LD DIDACTIC GmbH · Leyboldstraße 1 · D-50354 Hürth · www.ld-didactic.com Tel: +49-2233-604-0 · Fax: +49-2233-604-222 · Email: info@ld-didactic.de · Technical alterations reserved...

This manual is also suitable for:

Cassy plus727 100727 110727 111727 101