HP 3325B Remote Operation Command Set
Th© HP 3325B uses the following forms for remote commands:
Command Form
Example
Example Description
<mnemonic>
AC
Amplitude Calibrate
<mnemonic> <data>
FU2
Square wave function select
<mn8monic> <rangeclata> <suffix>
AM1.2V0
Amplitude of 1.2 Vpp
<mnemonic>?
FR?
Interrogate frequency
<mnemonic>
fFR
Interrogate frequency
where:
• CnmemomO is the HP-IB mnemonic
<suffix> is an alphabetic code for units, function, or mode
<data> is a numeric code for a function or mode
<range data> is the value for an entry parameter
" ? is used to interrogate the HP 3325B.
A program string for the HP 3325B may contain multiple HP-IB commands such as
"FU2 FR 1 MH AM 2 VO FR?"