Specifications
Table 3-1. Specifications, Continued
Option 001 High Stability
Frequency Reference
Aging Rate:
± 5 X10'^/week, after 72 hours continuous
operation: ± 1 x 10*' mo„ after 15 days continuous
operation.
Warm-up Time:
Reference will be within ±
1
x 10*^ of final value 15
minutes after tum-on at 25*C for an off time of less
than 24 hours.
Option 002 High Voltage Output
Frequency Range: l/^Hztol MHz
Amplitude:
Range: 4.00 mV to 40.00 Vpp In 8 ranges, 4-12-40
sequence, Into 500Q <500 pF load. Ranges are
four times the standard Instrument ranges, without
dc offset.
Accuracy: ± 2% of full output for each range at
2 kHz.
'
Flatness: ± 10% relative to programmed amplitude.
Sinewave Distortion:
Harmonically related signals will be less than the
following levels (relative to the fundamental full
output into 500Q, load):
10 Hz-50 kHz: -65dB
50 kHz-200 kHz: -60dB
200 kHz-1 MHz: ~ 40 dB
Square Wave Rise/Fall Time:
± 125 ns, 10% to 90% at full output, with 500Q,
500 pFIoad.
Output impedance:
<2£2atdc, <10Qat1 MHz
DC Offset:
Range: 4 times the specified range of the standard
instrument.
Accuracy; ± (1 % of full output for each range
+ 25mV).
Maximum Output Current:
± 20 mA peak
General
Operating Environment:
Temperature: 0''Cto55"C
Relative Humidity: 95%, 0°Cto40"C
Altitude; <15,000 ft.
Acoustic Noise Emission:
LpA < 70 dB (sound pressure level)
operator position
normal operation per ISO 7779
Power:
100/120/220/240V, +
5
%, - 10%; 48 to 66 Hz;
90 VA, 120 VA with all options
Weight;
9 kg (20 lbs) net; 14.5 kg (32 lbs) shipping
Dimensions:
133.4 mm high x 425.5 mm wide x 498.5 mm deep
(5 174" H
X
16 3/4" W
X
19 5/8" D)
3-10