Advertisement

Quick Links

Read the Information for Use and the Safety Instructions
carefully. Subject to modification without prior notice.
Typographical and other errors do not justify any claim for
damages. Modification of the product is prohibited.
This manual is designed for electricians, system administrators,
and product users.
All product names and trademarks mentioned in this manual are
trademarks of their respective owners.
Except for internal use, relinquishment of the instructions to a
third party, duplication in any type or form - also extracts - as
well as exploitation and / or communication of the contents is not
permitted.
Downloads and more information at:
www.ecue.com
Information for Use
Edition:
06.07.23 [EN_Butler_S2_Setup_v2p0]
Published by:
Traxon Technologies Europe GmbH
Karl-Schurz-Strasse 38
33100 Paderborn, Germany
©2023 Traxon Technologies Europe GmbH
All rights reserved
Traxon Technologies Europe GmbH
Sales Operations
Karl-Schurz-Str. 38
33100 Paderborn, Germany
+49 5251 54648-0
support@ecue.com
AB436200031
e:cue
Butler S2

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the e:cue Butler S2 and is the answer not in the manual?

Questions and answers

Summary of Contents for Traxon Technologies e:cue Butler S2

  • Page 1 33100 Paderborn, Germany All product names and trademarks mentioned in this manual are trademarks of their respective owners. ©2023 Traxon Technologies Europe GmbH Except for internal use, relinquishment of the instructions to a All rights reserved third party, duplication in any type or form - also extracts - as well as exploitation and / or communication of the contents is not permitted.
  • Page 2 Status LEDs System configuration Using the standalone web interface Online configuration Basic Butler S2 settings Network parameters Setting Device Properties Firmware update Dismounting Certifications Dimensions WWW.TRAXON-ECUE.COM ©2023 traxon technologies. All rights reserved. Information for Use 07/23 Sheet: 02 / 15...
  • Page 3: Safety Instructions

    General device description The e:cue Butler S2 is a DMX/RDM engine that can be used either in standalone mode to replay and loop previously uploaded lighting shows, or as a DMX output device controlled by another e:cue server with an e:net connection.
  • Page 4 0.25 … 1 mm² 2 x RJ45, USITT DMX512-A/RDM E1.20 Pin 1: DMX– Pin 2: DMX+ Pin 3: DMX Ground Galvanic isolation: 1000 V WWW.TRAXON-ECUE.COM ©2023 traxon technologies. All rights reserved. Information for Use 07/23 Sheet: 04 / 15...
  • Page 5 »A« This Butler S2 is a master. »b« This Butler S2 runs in slave mode. »d« The Butler outputs DMX. The number of cuelists is displayed as a single digit. WWW.TRAXON-ECUE.COM ©2023 traxon technologies. All rights reserved. Information for Use 07/23 Sheet: 05 / 15...
  • Page 6: General Remarks

    Only transport the device in its original packaging. This protects the device from damage. Unpacking Only unpack the e:cue Butler S2 at its installation location. To protect the device against condensation water, unpack it and wait until all moisture remaining in the device has evaporated. Condensation can occur when the device is moved from a cold to a warm location.
  • Page 7: Installation

    When using Power-over-Ethernet do not connect any power supply physically to the DC Input of the Butler S2. Otherwise the power feed from Ethernet will not be recognized. WWW.TRAXON-ECUE.COM ©2023 traxon technologies. All rights reserved. Information for Use 07/23 Sheet: 07 / 15...
  • Page 8: System Button

    Do not remove the SD card while the Butler S2 is in operation! Status LEDs e:net Link OFF: no Ethernet link ON: link established e:net Activity OFF: no data transfer ON: Ethernet data exchange in progress WWW.TRAXON-ECUE.COM ©2023 traxon technologies. All rights reserved. Information for Use 07/23 Sheet: 08 / 15...
  • Page 9: System Configuration

    To change the configuration, click the Configure button and enter the password. The default password is “ecue”, it can be changed during configuration. Click Enter and the main configuration dialogue gets displayed. Change the parameters (explained in the following chapter) and click Submit. WWW.TRAXON-ECUE.COM ©2023 traxon technologies. All rights reserved. Information for Use 07/23 Sheet: 09 / 15...
  • Page 10 Select the Network tab from the upper left window to see network configuration and settings. Here you should see all devices in the network segment including the Butler S2. If you need more details see the System Manual for the Lighting Application Suite, also available for download from the Traxon Technologies website.
  • Page 11 Do not modify the Advanced Settings, if you are not fully aware of the results. Close the Network Configuration Dialogue, the changes will be transferred to the Butler S2. You can now WWW.TRAXON-ECUE.COM ©2023 traxon technologies. All rights reserved. Information for Use 07/23...
  • Page 12 Click OK to connect the Butler S2 to the Programmer as DMX output device. The Device Manager now shows the Butler S2 in his device overview. WWW.TRAXON-ECUE.COM ©2023 traxon technologies. All rights reserved. Information for Use 07/23 Sheet: 12 / 15...
  • Page 13 Not used at the moment. The Butler S2 is now configured and can be used as DMX output engine or as standalone engine after uploading shows. WWW.TRAXON-ECUE.COM ©2023 traxon technologies. All rights reserved. Information for Use 07/23 Sheet: 13 / 15...
  • Page 14: Firmware Update

    Before dismounting, appropriate measures must be taken to protect the respective components against damage caused by electrostatic discharge (ESD protection). Disconnect all attached cables. Dismount the e:cue Butler S2. The dismounting is completed. WWW.TRAXON-ECUE.COM ©2023 traxon technologies. All rights reserved.
  • Page 15 Cert. to CSA Std. C22.2 No. 60950-1 12 Dimensions All dimensions in mm 71.5 63.5  content DMX/RDM e:net DMX2 DMX1 IEEE 802.3af Please check for the latest updates and changes on the Traxon website. © 2023 TRAXON TECHNOLOGIES. ALL RIGHTS RESERVED. www.traxon-ecue.com...

This manual is also suitable for:

Ab436200031

Table of Contents