Installation
Before you use your new FAVORIT dish¬
washer, you should make the following
checks:
Removal of packing
During transit the outlet hose is atta¬
ched to the machine at the underside,
with plastic tape. Tilt the machine back¬
wards and remove the plastic tape.
When returning the machine to its ori¬
ginal position, make sure that the outlet
hose lies freely against the left hand
side of the appliance and is not crushed
on the floor. The two baskets are secu¬
red by wooden blocks, inside thewasher
tub.
Open the door and remove supporting
wooden blocks and corrugated card¬
board packaging.
The lower left hand basket assembly is
secured by transparent adhesive tape
inside the lower basket.
Pull off adhesive tape.
Dimensions:
With worktop
Height 85 cm
Width 60 cm
Depth 60 cm
Without worktop
Height 82
cm
Width 59.5 cm
Depth 57.5 cm
The appliance must stand level — If In
doubt use a spirit - level (maximum
permissible deviation 2°). If necessary
adjust front feet.
Weight:
Free standing model approx. 72 Kg net
Built-in/under model approx. 68 Kg net
The Appliance has adjustable feet at the
front and fixed rollers at the rear.
Permanent fitting In kitchens:
Seek
advice
from
your
Specialist
Retailer from whom you purchased the
appliance.
Dimensions of Decor panels
(for built-under model)
Door
457.5 X 589.5 - radius 11
Lower panel
120.5X5B9.5- radius 11
Electrical connections
A. C. Current
220 V
(U. K.-version 240 V)
Connected load
3.4 kW
(U. K.-verslon 3.1 kW]
Plus 13 amp-fused
Green and yellow
Earth
Blue
Neutral
Brown
Live
As the colours of this mains lead of this
appliance might not correspond with the
coloured markings identifying the ter¬
minals in your plug, connect as follows:
The green and yellow wire must be
connected to the terminal In the plug
which is marked with the letter "E" or by
the earth symbol or coloured green or
green and yellow. The wire which is
coloured
brown
must
be
connected
to the terminal marked with the letter
"L" or coloured red. The wire which is
coloured blue must be connected to the
terminal with the letter "N" or coloured
black.
Water supply
The high pressure hose (Vs' = 10 NW,
1.55 m long) with 3U" hose coupling com¬
plete with sealing washers Is supplied. We
recommend not to use other washers
which may be of inferior quality. It is suffi¬
cient to tighten the nuts by hand but if a
spanner is used proceed very carefully.