Specifications - Yaesu G-1000SA User Manual

Antenna rotator & controller
Table of Contents

Advertisement

Power Supply Voltage:
Power Supply Current Consumption:
Rotor Voltage:
360° Rotation Time (Non Loaded):
Rotation Range:
Rotation Torque:
Braking Torque:
Maximum Vertical Load:
Mast Outside Diameter:
Braking Type:
Antenna K Coefficient:
Wind Loading Area:
Maximum Continuous Duty:
Operating Temperature Range:
Rotator Dimensions:
Rotator Weight:
Controller Dimensions:
Controller Weight:
Page 10

Specifications

G-800SA
117 VAC, 50/60 Hz
1A
20 VDC
Approx. 55 second
450° +0°/–5°
800 kgf-cm (58 ft-lbs)
4,000 kgf-cm (289 ft-lbs)
200 kg (441 lbs) or less (continuous) 200 kg (441 lbs) or less (continuous)
800 kg (1764 lbs) (momentary)
φ 38 to φ 63
Mechanical & Electrical stoppers
180 or less
0.75 m x 0.6 m or less (Pole Type)
2 m or less (Tower Type)
3 minutes
0 °C to +40 °C (Controller)
–20 °C to +40 °C (Rotator)
φ 186 x 300 mm ( φ 7.3 x 11.8 inch)
Approx. 3.6 kg (7.9 lbs)
200 x 130 x 193 mm
(7.8 x 5.1 x 7.6 inch)
Approx. 2.8 kg (6.2 lbs)
Rotator Attachment Dimensions
G-800SA/G-1000SA User Manual
G-1000SA
117 VAC, 50/60 Hz
1A
20 VDC
Approx. 55 second
450° +0°/–5°
800 kgf-cm (58 ft-lbs)
6,000 kgf-cm (434 ft-lbs)
800 kg (1764 lbs) (momentary)
φ 38 to φ 63
Mechanical & Electrical stoppers
230 or less
0.75 m x 0.6 m or less (Pole Type)
2.2 m or less (Tower Type)
3 minutes
0 °C to +40 °C (Controller)
–20 °C to +40 °C (Rotator)
φ 186 x 300 mm ( φ 7.3 x 11.8 inch)
Approx. 3.6 kg (7.9 lbs)
200 x 130 x 193 mm
(7.8 x 5.1 x 7.6 inch)
Approx. 2.8 kg (6.2 lbs)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

G-800sa