Section 4

Setup and Operation

Overview

The operator interface panel is shown in Figure 4-1.
Potentiometers
P1 P6
S1
DIP Switch
(All OFF =
factory settings)
POWER
LED is on when AC input power is applied to the control.
FAULT
LED is on when a fault condition is present in the control.
FWD
Press FWD to initiate forward rotation of the motor, in local command mode.
LED is on when control is in forward run mode.
REV
Press REV to initiate reverse rotation of the motor, in local command mode.
LED is on when control is in reverse run mode.
STOP
Press STOP to initiate a stop sequence, in local or remote modes. Depending
on the setting of potentiometer P2, the motor will either ramp or coast to a
stop.
4-1 Setup and Operation
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Figure 4-1 Operator Interface
POWER
FAULT
40 50 60
FWD
30
REV
20
10
STOP
0
% Speed
P1
P2
P3
P4
P5
1
L1 L2 L3
R2 R1
B-
Power
Motor
GND
GND
The LED is on when the control is in stop mode.
70
80
90
100
P6
J4 Control Terminal Strip
J5 Power Terminal Strip
T1 T2 T3
MN715P