115VAC 1 Phase Wire Size and Protection Devices

Control
Output
Fast Acting
Rating
HP
0.33
0.5
0.75
1.0
Note: All wire sizes are based on 75°C copper wire, 1% line impedance.
Figure 3-4 Single Phase AC Power and Motor Connections
L1
N
L1
L2
Baldor
Series 15P
Control
T1
T2
T2 T3
T1
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
MN715P
Table 3-4 Wire Size and Protection Devices - 1 phase
Input Fuse
Time Delay
Amps
Amps
10
10
10
10
15
10
20
15
Earth
Shield wires inside a metal conduit.
L3
Motor wire should be sized using the 3 phase
T3
information in Table 3 3.
Metal conduit should be used to shield output wires
(from T1, T2, T3 of control to T1, T2, T3 of motor).
G
AC Motor is not provided with control.
Wire Gauge
2
AWG
mm
14
2.08
14
2.08
14
2.08
14
2.08