TUNER SECTION
fL: Low-range frequency
fH: High-range frequency
• • • • • AM IF/RF
Signal generator: 400 Hz, 30%, AM modulated
Frequency
Test Stage
AM IF
450 kHz
AM Band
Coverage
AM Tracking 990 kHz
*1. Input: Antenna
Output: TP302
*2. Input: Antenna
Output: TP301
• • • • • FM RF
Signal generator: 1 kHz, 40 kHz dev., FM modulated
Test Stage
Frequency Frequency
Display
FM Band
87.50 MHz
Coverage
FM RF
98.00 MHz 98.00 MHz
(10-30 dB)
*1. Input: Antenna
Output: TP301
*2. Input: Antenna
Output: Speaker terminal
• • • • • FM IF
Signal generator: 10.7 MHz, FM modulated
Test Stage
Frequency Frequency
Display
IF
10.7 MHz
98.00 MHz
*1. Input: Antenna
Output: TP301
MAIN PWB
FM BAND
COVERAGE fL
R381
TP301
1
L312
T303
AM TRACKING
fL
Figure 11-1 ADJUSTMENT POINTS
Frequency
Setting/
Instrument
Display
Adjusting
Connection
Parts
1,602 kHz
T351
*1
531 kHz
(fL): T306
*2
1.1 ± 0.1 V
990 kHz
(fL): T303
*1
Setting/
Instrument
Adjusting
Connection
Point
T301 (fL):
*1
1.3 V ± 0.1 V
L312
*2
Setting/
Instrument
Adjusting
Connection
Point
T302
*1
(Turn the
core of trans-
former T302
fully counter-
clock wise)
T301
T351
AM IF
T302
FM IF
FM RF
T306
R356
TP302
AM BAND
COVERAGE fL
CD SECTION
• Adjustment
Since this CD system incorporates the following automatic
adjustment functions, readjustment is not needed when
replacing the pickup. Therefore, different PWBs and pickups
can be combined freely.
Each time a disc is changed, these adjustments are
performed automatically. Therefore, playback of each disc
can be performed under optimum conditions.
Items adjusted automatically
(1) Offset adjustment (The offset voltage between the head
amplifier output and the VREF reference voltage is
compensated inside the IC.)
* Focus offset adjustment
* Tracking offset adjustment
(2) Tracking balance adjustment (waveform drawing
Fig.11-2 EFBL)
(3) Gain adjustment (The gain is compensated inside the IC
so that the loop gain at the gain crossover frequency will
be 0 dB.)
* Focus gain adjustment
* Tracking gain adjustment
CD ERROR CODE DESCRIPTION
Error
When Pickup set inner position, inner switch
01
cannot detect 'ON' level for 10 secs.
When tray moves to Open/Close, Open/Close switch
cannot detect 'ON' level for 7 secs.
10*
When disc table rotate to target position.
Clamp switch cannot detect 'ON' level for 7 secs.
When disc table set to Disc1 position for 1 st time,
11*
"CLAMP SW", "DISC NO SW" and "OPEN/CLOSE"
cannot detect 'ON' level for 14 secs.
When it changes to CD function, DSP cannot read
31
initial data.
* 'CHECKING'
If Error is detected, 'CHECKING' will be display instead of 'ER-
CD**' display. 'ER-CD**' display will only be display when
error had been detected for the 5 th times.
T
Stopped
CH1=500 mV
CH2=200 mV
DC 10:1
DC 10:1
T
FDO
1
TE
3
EFBL
2
=Filter=
=Offset=
Smoothing : ON
CH1 :
BW : FULL
CH2 :
CH3 :
CH4 :
– 11 –
CD-E800W
Explanation
1999/04/05 20:26:47
CH3=1 V
DC 10:1
=Record Length=
0.000 V
Main :
100K
Mode : SINGLE
0.000 V
Zoom :
2k
Type : EDGE CH1
0.00 V
Delay :
Hold off :
0.00 V
Figure 11-2
500 ms/div
(500 ms/div)
NORM:20 kS/s
CH2
v/DIV
200 mV
=Trigger=
0.0 ns
0.2 µs