  • Page 1 Marsden MG-4800 User Manual Please take time to read these instructions before starting to use the scale.
  • Page 2 Thank you for choosing this Marsden hand grip dynamometer. This device has been designed for simple and straightforward use. Please use this document as guidance for most effective use. If you need help with using the MG-4800 and cannot find the information you need in this document, please call Marsden on 01709 364296 or email sales@marsdengroup.co.uk.
  • Page 3 If any inaccuracies occur, please contact your local dealer or service partner. • If you are in the UK, service contracts are available from Marsden to keep your scale accurate and reliable for longer. Call 01709 364296 for more information.
  • Page 4 Correct Grip Posture Page 4 of 16...
  • Page 5 Instruction for Battery Installation MG-4800 uses a CR-2450 lithium battery. Please read the following instruction before replacing the battery. 1) Remove the battery cover by turning anticlockwise. Install the new CR-2450 lithium battery. 3) Lock the battery cover by turning clockwise.
  • Page 6 LCD Display Key Functions /ZERO : Power on / Power Off / Zero Press to Power On, hold for 3 seconds to Power Off. Press to ZERO the value. Mode: Mode selection. Set : Real Mode: Unit switches. Other modes: digit adjusts. Please release the device before zeroing the value.
  • Page 7 Mode Switching • The following procedure gives you a specific idea of how to use the Medical Handgrip Dynamometer. • Please note that Real Mode is the default mode. If the device is powered off in any other modes. Next time it will start with the last mode selected prior to being powered off.
  • Page 8 Mode Description Real Mode The Real Mode is a dynamic mode. The force value fluctuates according to the gripping force during usage. Real Time Display: Following is an operation process. Page 8 of 16...
  • Page 9 Count Mode The Count Mode is for physician to set up a rehabilitation program for a patient to do rehabilitation exercise with exact force measurement. For Example: Set up target grip force before use. NOTE: Only if the force reaches the target is counted one times. Setup Target Grip Force: Page 9 of 16...
  • Page 10 AVG Mode The AVG Mode is for physician to evaluate the average of both hand’s force. For example: Grip once individually with right and left hand, then press SET to calculate average value of last two grips. NOTE: The force must be greater than 2kg Page 10 of 16...
  • Page 11 Max Mode The MAX Mode presents the maximum force of an impaired hand. Medical professions can evaluate the condition of patient’s impaired hand through the results. For example: Page 11 of 16...
  • Page 12 Counting Error (Too Low) The force is lower than the limit when power on, please increase the force and power on again. If the problem still exists, please contact Marsden. EEPROM Error The device has encountered internal error; please contact Marsden.
  • Page 13 Page 13 of 16...