  • Page 1 Control User manual V 1.5.0...
  • Page 2: Legal Notes

    PNX12-20001 This user manual contains the most important information for operating the Control 12 in a safe manner. Please study this manual carefully before using the device. This applies to all per- sons who come into contact with the device.
  • Page 3: Warning Symbols And Signal Words Used In This Manual

    Warning symbols and signal words used in this manual Warning symbols and signal words used in this manual Warning Obey warning to avoid death or serious injury Caution Obey instructions to avoid personal injury or damage to property Note Instructions and facts to be followed Additional, useful hints Important safety instructions, please read before installation! Warning...
  • Page 4: Table Of Contents

    6.3.2 Using a power supply unit in the flush-mounted box 6.4 Connecting and mounting the panel 7 Initial commissioning and operation 7.1 Switching the Control 12 on and off 7.2 Activating keyboard input 7.3 Setting up the visualisation 8 Maintenance 8.1 Cleaning the touchscreen...
  • Page 5 Table of Contents 9.1 Touch panel stops responding 9.1.1 Turning the panel off and back on 9.1.2 Disconnecting the panel from the power supply 9.2 Windows has unrecoverable problems 9.3 Technical support 10 Technical data Subject to change without notice Conformity Disposal notes Declaration of Conformity...
  • Page 6: Target Audience

    9.3 Technical support. 2 Intended use Depending on the software used, the Control 12 serves as control unit for the entire KNX instal- lation across rooms. It thus also serves as a status display. The device must be operated within the scope of the technical data and instructions given in this manual.
  • Page 7: Product Description

    Unauthorized repairs or changes to the device ▪ 3 Product description The Control 12 (short: panel) is a high-quality panel computer for wall mounting. It serves as a display and control unit for the KNX controlled components and installations of a building. 3.1 Software The panel can be operated both with the supplied YOUVI software and with other Windows- compatible software.
  • Page 8: Operation With Third-Party Software

    You will find a list of compatible software in the FAQs: www.peaknx.com/en/faq, topic “compatibility”. Further instructions such as for setting up the panel as a door station can be found in the download area: https://www.peaknx.com/de/downloads.
  • Page 9: Installation Options

    3 Product description 3.3 Installation options 3.3.1 Flush-mounted version 3.3.2 Wall-mounted version Position Description Position Description Flush-mounted box Wall-mounted frame Panel Panel Glass cover Glass cover...
  • Page 10: Touch Panel, Front View

    3 Product description 3.4 Touch panel, front view 3 Product description Position Description 4 x intake for glass cover Left: On/Off button, middle: activates status LED (C6), right: actuation > 5 s starts KNX reset 4 x slotted holes for fixing the panel Microphone Camera Status LED:...
  • Page 11: Touch Panel, Rear View

    3 Product description 3.5 Touch panel, rear view Position Description 1000 Mbit Ethernet port KNX-Wago 243-211 installation terminal USB C 3.2 Gen2 Status LED: ▪ Green: voltage in the correct range ▪ Red: over- or undervoltage, remove the power supply! ▪...
  • Page 12: Notes On The Panel's Ports

    A terminal of the following specification is used for the KNX connection: KNX WAGO 243 211, conductor diameter: 0.6-0.8 mm. Note: The KNX fieldbus can only be used with PEAKnx software. 3.6.2 Power supply The plug-in terminal for power supply has a usable wire cross-section of 0.75 to 1.31 mm².
  • Page 13: Scope Of Delivery

    Network connector ▪ Network patch cable ▪ Optionally included in scope of delivery: ▪ Glass cover ▪ Flush-mounted box or surface-mounted frame ▪ Recovery USB flash drive ▪ Control 12 power supply unit for the switch cabinet (recommended) or flush-mounted box...
  • Page 14: Important Safety And Handling Information

    6 Installation and start-up The Control 12 can be mounted to the wall flush (flush-mounted box PNX12-1000), completely flush with the wall (with flush-mounted box and adapter frame PNX12-10021) and surface-moun- ted (surface-mounted frame PNX12-10005).
  • Page 15: Preparation

    6 Installation and start-up 6.1 Preparation Note: We recommend hedging the panel, since in rare cases the panel must be taken com- pletely from the power supply, see section 9.1.2 Disconnecting the panel from the power supply. Necessary accessories for the installation of the panel: ▪...
  • Page 16: Installation In A Cavity Wall

    6.3.2 Using a power supply unit in the flush-mounted box Particularly, when replacing a foreign device with the Control 12, a power supply is often already present in the flush-mounted box. This means that mains voltage and low voltage are in the same housing and if connected incorrectly, even parts that normally only carry low voltage unintentionally may carry mains voltage.
  • Page 17 Connect the mains cable to the 230 V side of the power supply unit. Grounding − When using a power supply unit in the flush-mounted box of the Control 12: − Connect the grounding in the flush-mounted box. Use the supplied grounding set:...
  • Page 18: Connecting And Mounting The Panel

    6 Installation and start-up − When using a power supply unit in a third-party flush-mounted box: − For this purpose, connect the earthing to the panel. Use the earthing set provided. 6.4 Connecting and mounting the panel Preparation ▪ Place the screws (M3x12) included in the scope of delivery within reach for fixing the panel within the flush-mounted box.
  • Page 19: Initial Commissioning And Operation

    The Control 12 starts automatically after being connected to a power supply. Note: In the delivery state, the panel automatically logs on with the user name Control 12 without a password. After the Login, additional users can be added at any time or further settings may be changed in the Windows Settings.
  • Page 20: Activating Keyboard Input

    8 Maintenance 7.2 Activating keyboard input To automatically display the keyboard when tapping on a text input field, do the following: Swipe into the screen from the right and select “All settings”. ▪ Select “Devices” > “Typing”. ▪ Under “Touch keyboard”, check the last item: “Show the touch keyboard when not in tablet ▪...
  • Page 21: Troubleshooting

    Opening the unit invalidates the warranty. 9.1 Touch panel stops responding If the Control 12 no longer reacts to input on the touchscreen (which may occur in rare cases following Windows updates), try to reboot the panel, see chapter 9.1.1 Turning the panel off and back on.
  • Page 22: Disconnecting The Panel From The Power Supply

    The restore process may take up to 30 minutes. During this time, the panel cannot be used for building control. Each Control 12 is provided with an image for restoring the software to the state of delivery. To restore the panel to this state, proceed as follows: Note: It is recommended to create a backup of the YOUVI server in YOUVI Configuration >...
  • Page 23: Technical Data

    10 Technical data 10 Technical data Supply Power supply specification 24 V DC; 2.5 A Connecting terminal, conduc- 0.75 to 1.31 mm² usable wire cross-section tor cross section Power consumption Operation Idle (display brightness = 50%): 6 W Peak load: 30 W Server operation without LCD: 4 W Computer system Processor...
  • Page 24 10 Technical data Periphery Speakers Broadband, stereo Microphone Room characteristics Webcam 5 megapixel WLAN WiFi 2,4 GHz, 5 GHz IEEE 802.11b/g/n/ac/ax Bluetooth Dimensions and weight Computer with panel 297 x 210 x 22.5 mm Glass cover 297 x 210 x 0.7 mm Computer with panel 1350 g Glass cover...
  • Page 25: Subject To Change Without Notice

    Subject to change without notice Subject to change without notice Content changes in this documentation, which serve the technical progress, are made without prior notice. This documentation has been prepared with great care and will be revised at regu- lar intervals. Nevertheless, we cannot guarantee complete accuracy. All known errors are elimi- nated in new editions.
  • Page 26: Declaration Of Conformity

    Declaration of Conformity EU Declaration of Conformity This declaration applies to the following product: Product name: Control 12 Item number(s): PNX12-20001 Manufacturer: PEAKnx GmbH Otto-Roehm-Strasse 69 64293 Darmstadt Germany We declare under our sole responsibility that the mentioned product is in conformity with...
  • Page 27 www.peaknx.com...

Table of Contents