Mirion Technologies BIODEX SURGICAL C-ARM TABLE 058-846 Instructions For Use Manual

Mirion Technologies BIODEX SURGICAL C-ARM TABLE 058-846 Instructions For Use Manual

Advertisement

Quick Links

SURGICAL C-ARM TABLE™
INSTRUCTIONS FOR USE
058-846
058-847
058-846-10
058-847-10
7 Vreeland Road, Florham Park, NJ 07932
(800) 631-3826 | (201) 825-9500 |
www.biodex.com
FN: 20-322-CLR Rev B 4/23

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BIODEX SURGICAL C-ARM TABLE 058-846 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Mirion Technologies BIODEX SURGICAL C-ARM TABLE 058-846

  • Page 1 SURGICAL C-ARM TABLE™ INSTRUCTIONS FOR USE 058-846 058-847 058-846-10 058-847-10 7 Vreeland Road, Florham Park, NJ 07932 (800) 631-3826 | (201) 825-9500 | www.biodex.com FN: 20-322-CLR Rev B 4/23...
  • Page 2 If the desired information is not found, contact a local distributor or technical support directly at FLO-TechSupport@mirion.com. Thank you, Biodex Contact information Manufactured by: Mirion Technologies (Capintec), Inc. 7 Vreeland Road, Florham Park, NJ 07932 (800) 631-3826 | (201) 825-9500 Fax: 201-825-1336 email: FLO-TechSupport@mirion.com...
  • Page 3: Table Of Contents

    Table of Contents 1. Introduction .......................... 8 Intended Use ........................8 Indications for Use ......................8 Contraindications ......................8 Control Made Easy ......................8 Free-Float Feature ......................8 2. Operating Instructions ......................10 The Locking Brakes and Swivel Casters ................. 10 Using the Hand-Held Controller ..................
  • Page 4 Definition of Symbols The following symbols and their associated definitions are used and implied throughout this manual. Symbol Definition Carefully read these instructions prior to use Operating Instructions Caution General Warning General Mandatory Action Dangerous Voltage “On” Power “Off” Power Pinch Point Earth (ground) Alternating Current...
  • Page 5 Serial Number Contains Lead CE Mark Authorized Representative in the European Community Product Certifications and Classifications The Surgical C-Arm Table has received the following certifications, and falls within the following classifications: IEC60601-1:2005 (Third Edition) + CORR1:2006+Corr 2:2007 + A1:2012 (or IEC 60601-1:2012 reprint) ●...
  • Page 6 Before Proceeding NOTE: The warnings, cautions and instructions provided in this manual must be read, followed, and kept available for consultation at all times. Observing the information, instructions and procedures presented throughout this manual is essential for using this product both properly and safely. SPECIFIC CAUTIONS Allow only qualified, trained personnel to operate or service this product.
  • Page 7 Important Safety Information CAUTION: Federal Law restricts this device to sale by or on the order of a physician, sonographer or other licensed professional. Follow the unpacking and assembly instructions document. Before using this equipment, read the entire operation manual carefully. Failure to read the manual may result in user error or injury.
  • Page 8: Introduction

    1. Introduction Intended Use The Surgical C-Arm Table 846 is designed for image-guided procedures where stability, access, and precise, quiet, vibration-free positioning are essential. A cantilevered low attenuation carbon fiber tabletop, with choice of contoured or rectangular design, accommodates portable or ceiling-suspended C-Arms.
  • Page 9 Figure 1.1. Parts and Adjustment Mechanisms. 1. Hand-Held Controller 2. Mushroom Top Control for Free-Float Motion 3. Locking Brakes and Swivel Casters...
  • Page 10: Operating Instructions

    2. Operating Instructions CAUTION: Refer to instruction manual before operating or servicing system. CAUTION: Hospital grade plug to be plugged into a hospital grade receptacle only to achieve grounding reliability. CAUTION: Before transferring a patient onto or off the table, ensure all four caster brakes are locked.
  • Page 11: Using The Hand-Held Controller

    Figure 2.1. Locking Brakes and Swivel Casters Figure 2.2. Head End Lock Bar Using the Hand-Held Controller The hand-held controller may be used to adjust table height. When not in use, the Hand-Held Controller can be hooked onto the metal loop on the restraining strap, or on the accessory rail. CAUTION: Before moving the tabletop, be sure that all I.V.
  • Page 12: Positioning The X-Y Free-Float Tabletop

    To adjust the table position, press and hold the appropriate switch on the Hand-Held Controller. The tabletop will move in the direction indicated by the switch. Release the switch when the tabletop achieves the desired position. Figure 2.5.The Hand-Held Controller. Positioning the X-Y Free-Float Tabletop The X-Y free-float tabletop is positioned using the mushroom top tabletop handgrips.
  • Page 13: Catheter Tray Extension

    Catheter Tray Extension The removable extension can be used to provide additional table length for accommodation of catheters within the patient’s sterile field. This makes the procedure easier, safer and reduces the risk of breaking the sterility of the catheters. To attach the Catheter Tray Extension, simply hook the Extension guides over the accessory rails at the foot end of the table and lower the extension into position.
  • Page 14: Maintenance And Cleaning

    3. Maintenance and Cleaning The Biodex Surgical C-Arm Table is virtually maintenance free. By following the instructions below at suggested time intervals, or as often as necessary, the table will remain in “like new” condition. 1. As required, cleanse all exterior surfaces and tabletop pads with a mild detergent solution, such as Parker Laboratories Protex Disinfectant or any one-step disinfectant that does not contain bleach.
  • Page 16: Specifications

    4. Specifications Dimensions: Overall: 97" l x 26" w (246 x 66 cm) with OR accessory rails Tabletop: 97" l x 24" w (246 x 61 cm) – choice of classic contoured or rectangular design Catheter Tray Extension (removable): 18" l x 24" w (45.7 x 61 cm) non-radiolucent Radiolucent Area: 75"...
  • Page 17: Optional

    Optional 056-850 IV Pole, Rail Mounted 056-865 Arm Board, Carbon Fiber, one arm 056-866 Arm Board, Carbon Fiber, two arms 058-051 Catheter Tray Extension (removable) 058-864 Arm Board, Surgical, Carbon Fiber 058-849 Clamp, Accessory, C-Arm Table 058-856 Radiation Shield, Head/Cervical 058-857 Radiation Shield, Thoracic/AB...
  • Page 18 7 Vreeland Road, Florham Park, NJ 07932 (800) 631-3826 | (201) 825-9500 | www.biodex.com...