Installation, use, maintenant
manual SPRING TOPCon
V 0.5
December 2023

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SPRING TOPCon and is the answer not in the manual?

Questions and answers

Summary of Contents for DUALSUN SPRING TOPCon

  • Page 1 English Installation, use, maintenant manual SPRING TOPCon V 0.5 December 2023...
  • Page 2: Table Of Contents

    2.1.2. Hail resistance ......................7 2.1.3. Operating temperatures ................... 7 2.1.4. Climate class ......................7 2.1.5. Recommended hydraulic flows for the panel SPRING TOPCon ........7 2.1.6. Maximum allowable pressures for the DualSun SPRING panel ........8 2.1.7. Heat transfer fluid ....................8 2.2.
  • Page 3 Installation, use, maintenant manual SPRING TOPCon 9. Technical appendices ........................38 9.1. Hydraulic pressure losses SPRING TOPCon ..............38 9.2. Thermal performance ....................... 38...
  • Page 4: Introduction

    Please read this installation manual thoroughly and in detail in order to be able to fully exploit the functionality of the product. DualSun disclaims all liability for defetcs and damages that would result from non-compliance with the installation instructions (improper use, incorrect installation, handling error, etc.).
  • Page 5: Photovoltaic Solar Standards

    The installation instructions and safety instructions must be met. Observe the regulations on the prevention of industrial accidents prescribed by professional associations, in particular those relating to work carried out on the roof. 1.3. Solar thermal standards FLASH and SPRING DualSun panels must be recycled...
  • Page 6: General Description

    Protected by several patents, the panel SPRING TOPCon produces 4 times more energy than a photovoltaic panel of the same surface. This innovative technology allows your panel to be used: •...
  • Page 7: Hail Resistance

    It is very important not to use copper in the hydraulic networks connected with the panels, as there would be a high risk of galvanic corrosion of the exchanger. 2.1.2. Hail resistance The panel SPRING TOPCon has hail resistance level RG3. 2.1.3. Operating temperatures Stagnation temperature of the panel is 80 °C.
  • Page 8: Maximum Allowable Pressures For The Dualsun Spring Panel

    2.2.1. Protection against fire / explosion Do not install the DualSun modules in the vicinity of highly flammable gases, vapours, or dust (e.g., next to a gas station or containers). The national and local fire prevention standards and regulations must be respected during installation.
  • Page 9: Transport

    • The location is dry and cool, • No object can fall on the module and thus damage it. WARNING If a DualSun module is damaged or broken, it must be replaced. Never install a damaged module. 2.3. Cleaning the surface of the modules The greater the degree of contamination of the surface of the PV system, the less the cells are able to absorb the energy contained in the incident sunlight.
  • Page 10 Installation, use, maintenant manual SPRING TOPCon DANGER Work at height: Refer to the recommendation published by the national risk prevention body.
  • Page 11: Mechanical Installation

    • acid rain • active chemical vapors or any other aggressive environment • DualSun modules must not be installed near flammable liquids, gases, hazardous materials or on any type of vehicle. • It is recommended to install the photovoltaic modules at altitudes below 2000 m 3.2.
  • Page 12: Static Roofing Requirements

    The solar installer must ensure that the roof structure can carry the additional weight of the hybrid system. 3.4. Installing DualSun modules The panels SPRING TOPCon can only be installed in portrait. DualSun does not provide the module fixing system: for proper installation, refer to the installation instructions for the chosen fixing system. NOTE The list of mounting systems compatible with DualSun modules is available in the “Mounting...
  • Page 13 The clamps are not supplied by DualSun. IMPORTANT It is important to make sure that the clamping brackets do not distort the top of the aluminium frame of the DualSun panel, this may weaken or even break the glass.
  • Page 14: Gap Between Spring Topcon And The Roof

    Finnned version Insulated version CAUTION The size of the manifolds on the rear face of the panels SPRING TOPCon must be carefully considered to avoid contact between the fittings and the surface of the roof covering. NOTE To ensure good air circulation between the panel and the roof, a distance of 30mm must be...
  • Page 15: Installation Areas On The Rails Of The Mounting System

    3.6. Installation areas on the rails of the mounting system DualSun panels are certified according to the IEC standard for a maximum mechanical load of 5400 Pa positive (snow) and -2400 Pa negative (wind) in a standard configuration with four stirrups along the long side.
  • Page 16 Installation, use, maintenant manual SPRING TOPCon Table 2. The mounting method has been tested outside the scope of IEC 61730 certification DSTFxxx-108M10T-03 ; DSTNxxx-108M10T-03 ; DSTIxxx-108M10T-03 Installation 4 clamps on the long side 6 clamps on the long side method...
  • Page 17 Installation, use, maintenant manual SPRING TOPCon Table 3. The mounting method has been tested outside the scope of IEC 61730 certification DSTFxxx-108M10T-03 ; DSTNxxx-108M10T-03 ; DSTIxxx-108M10T-03 Installation 4 bolts in the mounting holes on the long 4 clamps on the short side...
  • Page 18 Installation, use, maintenant manual SPRING TOPCon WARNING No element fixed on the rails can be in contact with the rear face of the panel. For example micro-inverter or optimizer. Use a mechanical mounting element suitable for the rails of the installation system to fix the...
  • Page 19: Electrical Installation

    Installation, use, maintenant manual SPRING TOPCon 4. Electrical Installation Electrical connection [19] Electrical fittings, cables and diodes [20] Bonding and lightning protection [22] Indirect lightning strike [22] 4.1. Electrical connection The nominal electrical parameters Icc, Vco and Pmax of the modules are determined under standard STC (Standard Test Condition) test conditions: illuminance of 1000 W/m²...
  • Page 20: Electrical Fittings, Cables And Diodes

    WARNING If additional PV modules must be installed in string with DualSun modules, their power and current must be equal to those of DualSun panels within the limits of manufacturers' tolerances Wiring in parallel For DualSun modules connected in parallel, a corresponding overcurrent protection must be used. To this end, a DC voltage fuse must be used to avoid reverse current.
  • Page 21 Never open the junction box The junction box of the DualSun module contains bypass diodes which are in parallel connection with the cell wires. If a hot spot occurs locally on one or more cells, the diode will enter into service to prevent the main current from flowing through the hot cells in order to limit overheating and loss of performance of the module.
  • Page 22: Bonding And Lightning Protection

    It is imperative to refer to the local regulations in force to comply with specific requirements DualSun modules must be bonded with prongs, lugs or other suitable means. Bonding can be done through the holes made for this purpose as part of each module. These holes allow the earth cable to be attached and connected to the equipotential bonding.
  • Page 23: Hydraulic Installation

    Installation, use, maintenant manual SPRING TOPCon 5. Hydraulic installation Hydraulic installation of solar panels SPRING TOPCon breaks down into 5 steps: Hydraulic connection of the panels Hydraulic balancing of panel fields [27] Connection of the panel field to the transfer circuit...
  • Page 24: Inlet-Outlet Kit

    Installation, use, maintenant manual SPRING TOPCon Installation of the panel by inserting the connectors into the fixed panel Securing the module with the brackets Repeat step 3 for each panel added GREASE HANDLING Be careful when handling grease not to put any inside the fitting. If by mistake you put some in, it is imperative to remove it with a wipe.
  • Page 25: Hydraulic Connection Of The Inlets-Outlets To The Panels

    Installation, use, maintenant manual SPRING TOPCon • Plugs • Blocker • Grease 5.3.1. Hydraulic connection of the inlets-outlets to the panels Necessary material : • Elbow fittings (with OR without probe slot) • Blocker • Grease Assembly steps:...
  • Page 26: Adding Plugs

    Installation, use, maintenant manual SPRING TOPCon • Insert the greased elbow fitting into the manifold • Locking the fitting with the blocker GREASE HANDLING Be careful when handling grease not to put any inside the fitting. If by mistake you put some in, it is imperative to remove it with a wipe.
  • Page 27: Hydraulic Connection Of The Inlets-Outlets To The Transfer Circuit

    It is therefore important to ensure hydraulic balancing when several lines of panels are connected to the same hydraulic circuit. Hydraulic balancing of panel fields for DualSun pressurized system [29] Hydraulic balancing of panel fields for DualSun solar swimming pool heating system...
  • Page 28: Selection Of Transfer Lines - Pressurized System

    Installation, use, maintenant manual SPRING TOPCon 5.5.1. Selection of transfer lines - Pressurized system WARNING It is very important not to use copper in the hydraulic networks connected with the panels, as there would be a high risk of galvanic corrosion of the exchanger.
  • Page 29: Hydraulic Balancing Of Panel Fields For Dualsun Pressurized System

    DN20 DN25 DN32 DN40 5.5.2. Hydraulic balancing of panel fields for DualSun pressurized system IMPORTANT The installation of isolation valves is necessary for: Improve the bleeding of the air contained in the hydraulic circuit during filling while com- missioning: Fill line by line in order to purge the air contained in the circuit more quickly...
  • Page 30 Installation, use, maintenant manual SPRING TOPCon Symbols used in diagrams 1. Hydraulic inlet 3. Shut-off valve 2. Hydraulic outlet 4. Balancing valve 5. Filling valve Homogeneous lines Hydraulic balancing by the Tichelmann loop principle can be adopted when the panel fields are identical with the same number of panels, placed in the same direction.
  • Page 31 Installation, use, maintenant manual SPRING TOPCon Pressurized system Portrait panels - 2 lines / Single orientation / 1 column - DN15 or DN26 Portrait links Pressurized system Portrait panels - 2 lines / Double orientation / 1 column - DN15 or DN26...
  • Page 32 Installation, use, maintenant manual SPRING TOPCon Pressurized system Portrait panels - 4 lines / Double orientation / 1 column - DN15 or DN26 Portrait links Pressurized system Portrait panels - 1 line / Single orientation / 2 columns - DN15 or DN26...
  • Page 33: Maximum Number Of Panels Per Hydraulic Line

    Installation, use, maintenant manual SPRING TOPCon IMPORTANT In the case of automatic balancing valves: Provide for the installation of bypass / isolation valves in parallel with the automatic balancing valves for commissioning filling (higher flow rate). In the case of manual balancing valves:...
  • Page 34: Insulation And Protection Of Piping

    Installation, use, maintenant manual SPRING TOPCon 5.7. Insulation and protection of piping For the SPRING TOPCon with heat pump coupling, the external pipes must not be insulated. Pipes inside the building can be insulated to limit condensation.
  • Page 35: Maintenance

    Installation, use, maintenant manual SPRING TOPCon 6. Maintenance CAUTION Maintenance operations and interventions on the solar system must be carried out by a competent and authorized specialist. We recommend an interval of 2 years between each operation. Hydraulic maintenance Heat pumps can indicate to you in the error messages the defaults originating from the cold source (pressure drop, loss of transfer liquid, etc.).
  • Page 36: Decommissioning Of The Installation

    For SPRING modules, once the installation has been emptied, the DualQuickfit quick couplings can be disman- tled using a special pliers, supplied in the essential kit. 7.3. Waste treatment When handling waste from a used DualSun system, the applicable regional and national regulations must be observed. DualSun is a PV Cycle member.
  • Page 37: Responsibilities

    For the other components of the installation, see the warranty conditions of the various manufacturers. 8.2. Disclaimer DualSun cannot be held liable in the following cases: • Failure to comply with the instructions contained in the Notice concerning the installation, use, operation and maintenance of the installation.
  • Page 38 Installation, use, maintenant manual SPRING TOPCon 9. Technical appendices 9.1. Hydraulic pressure losses SPRING TOPCon Hydraulic pressure loss SPRING TOPCon in kPa for a panel according to the flow in L/h for a temperature of 25°C: 9.2. Thermal performance Figure 1. Thermal power of the panel in Watt as function of (T ), for G=0W/m²...