D A T A ( B I T ) R A T - Motorola OM 2000 Installation & Operation Manual

Out of band modulator, software version 1.0.x
Hide thumbs Also See for OM 2000:
Table of Contents

Advertisement

APPENDIX A — SPECIFICATIONS
Interconnection Specifications
Ethernet port
N e t w o r k d a t a r a t e - 1 0 0 M b p s m a x i m u m
OM 2000 data rate 2.005 Mbps output maximum
I n t e r f a c e
I E E E
8 0 2 . 3
I m p e d a n c e
1 2 0
o h m s
C a b l e
S h i e l d e d
t w i s t e d
p a i r
C o n n e c t o r
R j - 4 5
( l O B a s e - T )
M e s s a g i n g
U D R T C P / I R
S N M P
Data (Bit) Rate
The RS-232 port supports asynchronous communications with the following baud
rates: 300, 600, 1200, 2400, 4800, 9600, 19200. The RS-232 port does not support
synchronous communication. There is no flow control with this port.
The RS-530 port supports asynchronous communications with the following baud
rates: 300, 600, 1200, 2400, 4800, 9600, 19200, 38400, and 57600. There is no flow
control with this port.
The RS-530 port also supports synchronous communication with data rates between
50000 bps and 2005000 bps. There is up to 4% of data rate error depending on the
rate selected. The data rate is only applicable when in Sync Internal mode. This is
when the OM-2000 is transmitting synchronous data and clock.