M O U N T I N G T H E O - Motorola OM 2000 Installation & Operation Manual

Out of band modulator, software version 1.0.x
Hide thumbs Also See for OM 2000:
Table of Contents

Advertisement

3 INSTALLATION
S e r i a l d a t a c a b l e s w i t h f e m a i e D B - 2 5
c o n n e c t o r s
Description (rear panei connections)
Required to connect to DB-25 port.
C a u t i o n !
The power cord must use 18-AWG, stranded-wire cable with a 3-conductor
plug appropriate for your ac-power outlet. Using the wrong power cord will
damage the OM 2000.
3. Obtain or fabricate any necessary cables. Check the cabling guidelines provided
in Appendix B, "Cabling Specifications," for the length restrictions, connector,
and cable or wire type for each connection required for your system.
Note: RS530 serial cables for use with the OM 2000 can be purchased from
Motorola. The RS530 cable part numbers are:
. RS530 Cable type 1 DSR to OM 2000 for HITSOT+ (PN: 523807-002-00)
• RS530 Cable type 2 Standard RS530 (PN: 471372-003-00)
4. Brace the unit with optional rear supports for improved stability when mounting
the OM 2000 into the equipment rack.
Mounting the OM 2000
Mount the OM 2000 in a standard 19-inch rack. If the equipment operates
continuously in a closed cabinet, use forced-air circulation to ensure maximum
equipment life and optimum performance.
C a u t i o n !
Improper grounding may damage the OM 2000. Refer to the national
guidelines or local standards for the OM 2000 proper grounding to equipment
racks and to the building grounding system.
To mount the unit in the rack:
1. Insert the four screws with the washers through the four mounting holes in the
front panel and into the mounting holes in the rack.
2. Install the optional rear supports, if desired, (part # 213883-000) to improve
stability.
3. Tighten all screws.