CE、 CB、 ETL certified. In addition, our products are tested and inspected strictly prior to shipment to ensure product quality and safety. At COTLIN we are very proud of our products and are completely committed to providing you with the best products and service possible. Your satisfaction is our number one priority.
Before Requesting Service Receiving and Inspection Please check the appearance of outer packaging box and the inner contents when receiving the goods to protect your right and interest. If there is any damaged outer packaging, defect and damage product, missing parts or received the ...
Page 5
➋ Take some pictures about the damage parts of the product and the whole image of the product(include parts all parts that have been received). e.g. ➌ Take some pictures about all the labels on the shipping box. e.g.
Page 6
➎ If the unit is delivered by a truck, please take the receipt with signature ( it must be noted: damaged / lost ) Step 3 Contact us with upon information, including serial number or model number, original ...
Page 7
If the problem continues after taking the proper remedial actions, disconnect the power cord plug from the wall outlet, transfer the items stored in the cooler to a box or other container, and please contact us with following information(service@cotlin.top) : Photos and videos of the trouble part. ...
INTRODUCTION The Merchandising Refrigerators are essential for the display and sale of packaged goods. This makes them invaluable for a variety of commercial businesses, including convenience stores, offices, supermarkets, restaurant, bar, hotel and any other place where grab-and-go food and beverage options are readily available.
Technical Specifications Model WX-UDC-P255 WX-UDC-P354 Capacity 9 cu.ft 12.5 cu.ft Voltage 110V/60HZ 110V/60HZ Dimensions(L*W*H) 21.18” x 20.67” x 69.76” 22.76” x 23.82” x 77.95” Weight 139LBS/63KG 172LBS/78KG Cooling System Fan cooling Fan cooling Compressor Embraco Embraco Refrigerant R290 R290 Temperature Range 34℉-50℉...
SAFETY PRECAUTIONS This manual contains the product’s basic knowledge, use instruction, fault diagnosis and basic trouble shooting methods. In order to better understand and use this product, please take good care of this manual and read it carefully. The purpose of the safety precautions in this manual is to ensure safe and correct use of the unit to minimize risks that could cause serious damage and injury.
Page 11
The appliance shall be disconnected from its power source during cleaning or maintenance and when replacing parts. When the cooler will be not be used for a long time, disconnect the power and clean it. Please examine ...
The symbol is a warning and indicates the refrigerant and insulation blowing gas are flammable. Warning - Risk of fire / flammable materials. Warning - Do not store explosive substances such as aerosol cans with a flammable propellant in the unit.
Precautions for Use Never splash water directly onto the All repairs, disassembly and modifications product or wash with water as short- should be performed only by qualified circuit and electrical leakage could result. technicians. Attempting to perform these yourself could result in a fire, malfunction, and injury.
Page 14
Install the unit in a location where the If you find gas leakage,please don't touch floor is sturdy enough to support the load the appliance. Turn it off and open the of the unit. If the floor is not sturdy doors and windows for ventilation.Gas...
Page 15
Grasp the handle when closing the door. Do not push hand against or apply Holding at other positions could result in excessive force to glass surfaces as the pinched fingers and injury. glass could break and cause injury. When disconnecting the power cord plug...
INSTALLATION Guides to Choose Location 1. The unit is for indoor application only. Outdoor use may cause decreased efficiency and a damage to the unit. 2. Due to the fact that the unit has a glass door, its performance is highly influenced by environmental conditions.
Electrical Safety Be sure to follow the National Electrical Code, as well as local codes and ordinances, when installing the receptacle. Before your new unit is connected to a power supply, check the incoming voltage. Please refer to the ...
Page 18
2. Mechanical temperature control service@cotlin.top COTLIN...
INSTALL AND ADJUSTABLE SHELF Shelf height adjustment. The shelf height can be adjusted. Arrange the shelves in accordance with the dimensions of the items to be placed in the cooler. How to Install the Fixer of Shelf Step 1 Put on the shelf.
How to Discharge the Fixer of Shelf Step 2 Take the other side off the hole Step 1 When discharge the fixer, push the fixer to one side and let another side gets away from the hole How to Install the K-Type Fixer of Shelf Step 1 Take out k-clip and align with hole.
OPERATION Before Use Remove shipping package, tape, etc, and leave doors open to ventilate for a while. The unit is cleaned before shipment. However, clean the compartment interior using warm water then dry it with a soft-cloth after delivery, for the glass parts only use specific products, avoiding the use of water which can leave on the glass residues.
NOTE: This machine has an internal temperature differential that works as a protection for the compressor. The way the differential works is that at whatever temperature the unit will be set at, the compressor will work and cool the cabinet down until it reaches the chosen set point then it will shut itself up.
MAINTENANCE & CLEANING The smooth operation and life of the equipment are mainly determined by correct and regular maintenance. It is much easier to clean on a regular basis than to have to remove stains once they have built up.
Periodically remove the shelves from the unit, and clean them with a mild soap and warm water. Rinse under tap afterwards to remove any soap residues. NOTE: Always dry the shelves before placing them back inside the chamber.
TROUBLE SHOOTING Fault Cause Resolution 1. Electronic temperature Open traverse or bad connection Check wires to ensure a good connection controller dis-function/flicker Have a fault on indicator Change the electronic controller Open traverse or bad connection Check wires to ensure good connection ...
PROCEDURES OF REPLACING PARTS Change Starter for Light Step 1 Remove back shell, find the faulted starter, press slightly and rotate counterclockwise until the starter can be taken out. Step 2 To insert the new starter into the holes, press slightly and rotate clockwise until the starter is fully installed.
Change Light Tube Change Inner Tubes Step 1 Step 2 Step 3 Open the glass door, remove Catch the both sides of tube, Clockwise install a new tube the screws of the tube cover counterclockwise rotate by 90 on tube holder, put on tube and take out the cover.
Change Air Fan Step 1 Step 2 Step 3 Remove screws on the fan Remove these 4 screws and Remove the screws of the board, put the whole board take off the fan cover. sensor, take off it and the down slowly, and disconnect fixed clip.
Change Temperature Display Step 1 Step 2 Step 3 Loosen screws, take off the Press raised jump ring on the Install new controller on shutter, disconnect wires of both sides of the temperature shutter, put on the jump probe and power wires.
WARRANTY COTLIN is committed to providing customers with premium commercial display cooler and we guarantee 30 days new replacement on quality problem; Provide lifetime technical service and troubleshooting support for any question. The following is not included in the free service: Without purchase records.
Need help?
Do you have a question about the WX-UDC-P255 and is the answer not in the manual?