INSTALLATION
Model 490-00 Series. These units are intended to be wired to the input terminals of Xantech Connecting
Blocks or other devices, using the supplied 3-terminal block in the remote room location. A 3-conductor
cable (refer to specifications above), is run to the main room. Connections are then made to a Xantech
connecting block, power supply and emitters as shown in the following illustration of a typical basic system:
While it is possible to make wired connections without the connecting block, it is not recommended. The
connecting block reduces installation time, helps to eliminate errors, allows easy troubleshooting and
permits easy system upgrades later, if needed.
Input connections must be made as illustrated. To extend the emitter wires to a more distant location, you
may splice in 2-conductor wire, in the wire gauges mentioned under "Specifications", as needed.
Model 490-30 Series. These units, equipped with a 7-foot cable and 3.5 mm stereo mini plug, are plugged
directly into the "IR RCVR" or "AUX" jack on Xantech Connecting Blocks, such as the CB12, CB20, 789-
44, 791-44, etc. The 490-30 should be used in installations where the connecting block is within reach of
the 7-foot cable -- such as when installing the 490-30 on a cabinet where the controlled equipment is behind
closed doors.
A typical system, with a 490-30, 781RG Power Supply and 282M Emitters plugged into a 791-44 Amplified
Connecting Block, is shown in the following diagram:
Mounting: Drill a 1/2" hole in any flat surface, such as a cabinet panel. Pass the lead and the body of the
490 through the hole and secure from the rear with the nut (supplied).
Affix the Mini-Emitters, such as the 282, 284, 283 and 286 series, to the IR sensor windows of the controlled
equipment in accord with the instructions that come with them.
2
490-00
Series
0.469"
IR Receivers
Hand Held
Remote
1 7/8"
3-Conductor
Inter-room Cable
Red (or white)
(unshielded OK)
Stripe
OUT
+12V
GND
7' Ribbon Cable
3-Terminal Block (supplied)
REMOTE ROOM
490-30
Series
IR Receivers
0.469"
1 7/8"
490-30
(mounted on or
7 Foot 3-Conductor
near cabinet in an
Cable with Quick
inconspicuous
Connect Mini Plug
location).
781RG
Power Supply
Hand Held
To 120 V AC
Remote
(Unswitched)
Controlled Equipment
(mounted behind
closed cabinet doors)
781RG
Power Supply
Satellite Receiver
To 120 V AC
(Unswitched)
283M
Blink-IR™
789-44
Connecting Block
VCR
283M
Blink-IR™
+12 VDC
AV Receiver
GND
STATUS
IR IN
283M
Blink-IR™
Mouse Emitter
MAIN ROOM
791-44
Amplified
Connecting Block
Satellite Receiver
283M
Blink-IR™
VCR
283M
Blink-IR™
AV Receiver
+ 1 2 V D C
G N D
S TAT U S
283M
I R I N
Blink-IR™
CD Changer
283M
Cassette DecK
283M
Blink-IR™
Mouse Emitter
Blink-IR™
490 Series

Advertisement

loading

This manual is also suitable for:

Micro link 490w-30Micro link 490-00Micro link 490dw-00Micro link 490w-00