CAME PXC08 Programming Manual
CAME PXC08 Programming Manual

CAME PXC08 Programming Manual

Security alarm control unit
Hide thumbs Also See for PXC08:

Advertisement

Quick Links

SECURITY ALARM
CONTROL UNIT
FA00458-EN
PROGRAMMING MANUAL
PXC08

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PXC08 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for CAME PXC08

  • Page 1 SECURITY ALARM CONTROL UNIT FA00458-EN PROGRAMMING MANUAL PXC08...
  • Page 2: Table Of Contents

    CONTENTS SYMBOLS AND GLOSSARY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PAG . TECHNICAL MENU .
  • Page 3: Technical Menu

    Technical menu ACCESSING TECHNICAL MENU TECH MENU ACCESS INSTALLER'S TECHNICAL CODE CODES Depending on the parameter -> ), access to the technical menu may or may not be preceded by the User code Simultaneous access from more than one keypad to the technical or user menu is not permitted INDIRECT ACCESS 123456 To access the Technical Menu hold down the...
  • Page 4: Easy Mode

    EASY MODE The EASY programming mode lets you quickly and simply start up low-complexity systems or is used by installers who are not experts on the security alarm system The pre-configured settings are the following: INDEX NUMBER AREA DESCRIPTION INDEX NUMBER AREA DESCRIPTION LIVING AREA PERIMETER AREA...
  • Page 5: System

    SYSTEM The system menu is used to define the components of the system (areas, keypads, readers, etc ), assign addresses to them, and carry out a whole series of tests For programming move on to the following menu headings MODIFY SYSTEM ▲...
  • Page 6: System Test

    SYSTEM TEST F S A ▲ Inputs test: SYSTEM 02 The open inputs test can be carried out on the whole system or just on some selected ▼ ▲ areas ▼ ▼ ▲ TEST SYSTEM Control unit tamper test: INPUTS TEST *=LAUNCH TEST Lets you check the control unit tamper status AREAS TO TEST...
  • Page 7: Scenarios

    SCENARIOS ▲ EXACT ON+OFF Area operation: (Default: SCENARIOS F S A ▼ ▲ Associated areas: ▼ The parameter defines the operation that the scenario has to carry out in the areas, from ▼ ▲ MODIFY SCEN. 01 ASSOC. AREAS among those specified in GOING OUT DISABLED The scenario does not alter the on/off status of the areas...
  • Page 8: Areas

    AREAS ▲ Force area: (Default: AREAS ▼ ▲ Forcing is the parameter which lets you define whether an area can be armed even when there are open inputs (in this case, when the exit time has elapsed, the area alarm will be ▼...
  • Page 9: Keypads

    KEYPADS ▲ Keypad type: (Default: KEYPADS ▼ ▲ Menu can be seen for addresses from “02” onwards, lets you choose whether the keypad is LCD (PXKTB01 or PXKTN01), or LED (PXKIB or PXKIN) ▼ ▼ ▲ MODIFY KEYPAD 01 DESCRIPTION Associated areas: (Default: KEYPAD TYPE 02 Associated areas are the areas which can be managed and viewed from the keypad These...
  • Page 10: Readers

    READERS ▲ Associated areas: (Default: INSERTERS ▼ ▲ Associated areas are the areas which can be managed by the reader These also represent an AND-type filter on the areas managed by the code and scenario ▼ ▼ ▲ MODIFY INSERT. Example: there is a flat above a ground-floor shop The owner wants to be able to manage INSERTER 01 the flat and the shop with the same key...
  • Page 11: Inputs

    INPUTS F S A ▲ EXCLUDED Status: (Default: INPUTS EXCLUDED ▼ ▲ An input is excluded when it is not used ARMED ▼ An input is armed when it is used in the system ▼ ▲ MODIFY INPUT 001 TEST An input is in test mode when you want to monitor the performance INPUT of an input through the events memory without triggering alarms...
  • Page 12 MEMORY Input active when the control unit is armed If it is closed (i e balanced) when the exit time has elapsed, it behaves like a normal immediate input On the other hand, if it is open when the exit time has elapsed (i e unbalanced), it is ignored until it is closed (i e balanced) and from that moment it behaves like a normal immediate input Example: memory inputs are defined as the inputs that the User decides to leave open...
  • Page 13 NEVER Immediate: (Default: Parameter visible only if the input is delayed in type Lets you manage the delayed input as an immediate one when it is partialised (or if associat- ed with multiple areas and not all the areas are on) NEVER Standard setting,...
  • Page 14 F S A Associated areas: (Default: The inputs can be freely associated with one or more areas The behaviour of an input associat- AREAS AND/OR AREAS ed with more than one area depends on the value selected for parameter ARM. IF AREAS OR And / or areas: (Default: If several areas are associated to an input the input's armed/disarmed status, given by the on/ off status of the associated areas, depends on this parameter:...
  • Page 15 ALWAYS Output command: (Default: Depending on this parameter, managing the output can be linked to whether the input is on or off ALWAYS The output is always commanded by the status of the input To be more precise: the output is activated if the input is unbalanced and reset if the input is balanced ARMED If the input is active, or one or more areas associated with it are...
  • Page 16: Outputs

    OUTPUTS ▲ STABLE Status: (Default: OUTPUTS 12 STABLE ▼ ▲ the output's activity follows the status of the associated event Example: the output is activated by the associated input being in ▼ ▼ ▲ MODIF.OUTPUT 001 an OPEN condition OUTPUT PULSE The activity of the output is determined by the associated event TYPE 001...
  • Page 17 NEGATIVE Security: (Default: NEGATIVE The output is normally deactivated and is activated when it is commanded Example: by connecting a relay to an open collector output with NEGATIVE SECURITY, the relay will normally be de-energised and will energise only when the output is activated SECURITY POSITIVE NEGATIVE...
  • Page 18: Times

    TIMES ▲ Autotest time: (Default: TIMES ▼ ▲ This sets after how many hours the control unit must regularly and automatically carry out an autotest of operation The first autotest after starting up the control unit is carried out after a ▼...
  • Page 19: Telephone Notifications

    TELEPHONE NOTIFICATIONS F S A ▲ Activating and restoring general syst. alarm (generic notification): TELEPHONE Telephone notifications associated with the activation and restoration of the system's gen- NOTIFICATIONS ▼ ▲ eral alarm Set the telephone numbers with the keys ▼ PHONE NOT.MENU 01 GENERAL ALARM Activating and restoring single areas' general alarm:...
  • Page 20: Telephone Notifications

    TELEPHONE NOTIFICATIONS F S A Activating system burglar alarm (generic notification): PHONE NOT.MENU 04 BURGLARY ALARM Activating system burglar alarm (generic notification): Telephone notifications associated with the activation and restoration of the system's bur- AREA B-AL.ACTV glar alarm (the alarm is given by the burglary inputs) Set the telephone numbers with the ######## keys AREA B-AL.RST...
  • Page 21 Entering code: PHONE NOT.MENU 07 ENTER CODES Telephone notifications associated with entering the code only from keypad + – With select the codes Set the telephone numbers with the keys ENTER CODE -------- PHONE NOT.MENU 08 ENTER KEYS Entering key: Telephone notifications associated with entering the key on the reader ENTER KEY + –...
  • Page 22: Associating Outputs

    ASSOCIATING OUTPUTS Associating the same output to several events or several areas (failures, alarms, etc ) gives the output the OR function Example: if the general alarm of all the areas status is associated with the same stable output, the output will be activated when at least one area is in alarm mode ▲...
  • Page 23: Codes

    CODES F S A ▲ Change technical code: CODES Lets you change the technical code (default 222222) ▼ ▲ ▼ TECHNICAL CODE INSTALLER WITH CTL-U OFF Accessing technical menu: (Default: MODIFY WITH CTL-U OFF Access to the technical menus is only allowed when the TECHNICAL CODE control unit is totally off (no area on) ▼...
  • Page 24 Associating output: (Default: Lets you associate a pulse-type output with the entry of the User code on the keypad ASSOC. OUTPUT 001 Example: used to be able to open a lock through entering a code Code group: (Default: Lets you associate codes with a group, so that they can be managed simultaneously The op- GROUP eration of this group can be enabled/disabled by the timer ENABLED...
  • Page 25: Keys

    KEYS F S A ▲ Check key: KEYS ▼ ▲ Lets you check whether a key is in the database and if it does exist the index number is displayed along with the description ▼ F S A ENABLED Activating code: (Default: CHECK KEY If you want to use a key it must be activated ▼...
  • Page 26: Phones

    PHONES F S A ▲ Telephone number: TELEPHONES ▼ ▲ Change the telephone number Having pressed the key, type the number with the num- ber keys and with the keys you can confirm or delete with To deactivate the number ▼...
  • Page 27: Telephone Options

    TELEPHONE OPTIONS ▲ 1-2-3-4 Call sequence: (Default: TELEPHONE Lets you choose whether, in the selection sequence for programmed telephone numbers, in the OPTIONS ▼ ▲ event of communications that are NOT successful (e g the number called is engaged), another ▼...
  • Page 28 Activating remote control by PSTN by the INSTALLER:(Default: PSTN REM.ASSIST. Lets you activate access to programming via remote PC on the PSTN line ▼ ▲ Activating remote control by GSM: (Default: RMT-CTRL. Lets you activate access to the voice guide via the GSM line Safe GSM: (Default: SAFE GSM By activating the remote control by GSM you can create a filter which checks incoming calls...
  • Page 29: Special Functions

    SPECIAL FUNCTIONS F S A ▲ AREAS STATUS Keypads display: (Default: SPECIAL The keypads are made up of two rows of 16 characters The date appears in the first row and SPECIAL in the second you can decide what to display from the following information: ▼...
  • Page 30: Programmer

    F S A DISABLED Description of firm and assistance: (Default: RST. SUPERVISION If activated, every time that a radio device is 'lost' the notification is repeated cyclically at the end DISABLED of the time set in the supervision window F S A Description of firm and assistance: (Default: DESCRIPTION Here you can enter the name of the installation company that will appear on the user menu under...
  • Page 31: Events

    Postponement: (Default: By activating the postponement of a programme step you can delay the operation from the User Menu PROG. AT STEP 01 POSTPON.:NO Example: if you want to delay the programmed arming of the system until 19:30 you need to set: Operation: 1;...
  • Page 32: Default Parameters

    IN PROCESS RESTORE KEYS? *=YES #=ESC ARE YOU SURE? A=YES #=ESC RESTORE KEYS IN PROCESS CONTROL UNIT VERSION F S A ▲ Checking the control unit version VERSION Displaying the control unit firmware version SECURITY ALARM ▼ ▲ KEYPAD PXC08 1.0.X...
  • Page 33: Events Messaging

    Events messaging Events are made up of: • TIME and DATE • EVENT DESCRIPTION (activation / restoration) • EVENT INDEX NUMBER • EVENT DESCRIPTION (part 2) Telephone notifications group ACTIVATING RESTORING DESCRIPTION 2 CAUSE There is an arming event when the only operations are (total or partial) arming.
  • Page 34 Telephone notifications group ACTIVATING RESTORING DESCRIPTION 2 CAUSE The tamper device on the radio receiver RADIO.MOD.TMP xx MODULE DESCR. module on bus xx has been tampered with. Check module tamper. The tamper device on keypad xx has been KYP TAMP.ALRM xx KEYPAD DESCR.
  • Page 35 Declaration of compliance Came S p A declares that this device complies with the basic requirements and with the other pertinent arrangements set by directive 1999/05/CE, 2006/95/CE and 2004/108/CE If required a copy of the original of the declaration of compliance is available...
  • Page 36 CAME S.p.A. Via Martiri Della Libertà, 15 Via Cornia, 1/b - 1/c 31030 Dosson di Casier 33079 Sesto al Reghena Treviso - Italy Pordenone - Italy (+39) 0422 4940 (+39) 0434 698111 (+39) 0422 4941 (+39) 0434 698434 www. came.com...